2- Remove the pre-punched rear opening with side cutters
3- Remove the baffle plates (as described in paragraph 1.5 in the "Cleaning and
maintenance" chapter), being careful not to damage any of the vermiculite plates;
4- Unscrew the 4 screws on the inside of the combustion chamber (Fig. 7) with an
Allen key to be able to rotate the flue gas spigot;
5- Position the flue gas spigot so that the outlet is horizontal;
6- Then retighten the four Allen screws and replace the baffle and baffle.
7- Assemble the back panel and place the cover as shown in figure 9.
.
The following steps must be observed when converting the external air connection:
Pic. 7
Pic. 8
1- Disassemble the back panel (A) by
unscrewing the 6 screws (pic. 10).
Then lift the back panel and take it
out;
2- Remove the rear pre-punched hole
(B) with a side cutter;
3- Fasten the external air connection
(C) to the stove using the supplied
nuts DIN 6923 M6 (D).
4- Reassemble the back panel in re-
verse order to 1.
Pic. 10
30
Pic. 9