Télécharger Imprimer la page

Wamsler SOSA Mode D'emploi page 21

Publicité

Les langues disponibles

Les langues disponibles

17. No flammable objects are placed or leaned against in the warming compartment or on /
on the device. Find safety distances!
18. Before the installation, the probable load-bearing capacity of the installation surface is
to be seen. If the load-bearing capacity is insufficient, a shim should be used to distribute
the load.
19. In spring and autumn, the chimney may no longer draw correctly, so that gases produced
by combustion are not completely removed. The fire chamber should then be filled with
a small quantity of fuel, ideally with wood shavings, and lit under supervision, in order to
stabilise the chimney draught. The grate must be clean.
20. After each prolonged period of use for heating, have the stove checked by a profes-
sional. The flues and pipes for the evacuation of fumes must also be thoroughly cleaned.
21. If repairs or replacements are necessary, please contact your supplier with the neces-
sary article numbers and serial numbers in good time. Only original WAMSLER replace-
ment parts may be used.
22. Work such as installation, setup, commissioning and services, as well as repairs, must
only be carried out by qualified personnel (heating system or space heating technicians).
Intervention by non-qualified persons invalidates the warranty and guarantee.
23. As the solid fuel oven/stove draws the air required for combustion from the surrounding
room, you must ensure that sufficient air can be drawn in through non-sealed windows
and outside doors. It can be assumed that is this is provided by a room volume of at
least 4 m³ per kW nominal heat capacity. If the volume is less than this, then air vents
can be used to provide access to further air in other rooms (min. 150 cm²).
24. You must ensure that the correct safety distance is maintained from all flammable com-
ponents and materials – to the side, rear and front. These distances can be found in the
Instructions for Use or the identification plate.
25. The fire chamber must not be modified.
26. Connection to a chimney whose functional height is less than 4 m, or if multiple stoves
are installed, 5 m, is not permitted. A maximum of two other fires can be connected to
the chimney which is to be connected the stove.
27. If the chimney catches fire immediately close all doors and openings and call the fire
brigade. Do not attempt to extinguish the fire yourself. Afterwards have the chimney
thoroughly checked out by a professional.
28. Solid fuels naturally create soot, so it is always possible that the window glass will be-
come dirty: this does not mean there is a malfunction.
21

Publicité

loading

Ce manuel est également adapté pour:

Gor188 17