BLUEHELIX PRO S 27 C
Fault code
Fault
F52
Heating sensor fault
A61
Controller fault ABM03C
No communication
A62
between controller and
gas valve
A63
F64
Controller fault ABM03C
A65
F66
A23
A24
F20
F21
Card parameter fault
A26
F40
F47
5. TECHNICAL DATA AND CHARACTERISTICS
196
22
81
16
35
278
221
42
10
8
7
44
fig. 26 - General view
Possible cause
Cure
Sensor damaged
Replace the sensor
Controller internal error
Check the earth connection and
ABM03C
replace the controller if necessary.
Controller not connected Connect the controller to the gas valve
Valve damaged
Replace the valve
Controller internal error
Check the earth connection and
ABM03C
replace the controller if necessary.
Wrong card parameter
Check the card parameter and modify
setting
it if necessary.
9
74
11
39
136
37
cod.
Table. 9 - Key of figures cap. 5
7 Gas inlet
8 Domestic hot water outlet
9 Cold water inlet
10 System delivery
11 System return
14 Safety valve
16 Fan
22 Burner
32 Heating circulating pump
35 Air separator
36 Automatic air vent
37 Cold water inlet filter
39 Flow regulator
42 DHW temperature probe
44 Gas valve
56 Expansion tank
191
72 Room thermostat (not supplied)
56
35
278
186
193
14
36
114
221
32
10
74 System filling cock
81 Ionisation/ignition electrode
104 Fuse
114 Water pressure switch
136 Flow meter
138 External probe (optional)
139 Remote timer control (optional)
154 Condensate drain pipe
186 Return sensor
191 Fume temperature sensor
193 Trap
196 Condensate tray
221 Bypass cock
256
278 Double sensor (Safety + Heating)
340 Bypass pipe
A ON/OFF switch (configurable)
193
154
74
340
39
136
42
37
8
9
fig. 27 - Water circuit