Fan control
Integrated cooling of the generator
The cooling is integrated within the plastic housing of the generator. The
operation of the fan is controlled by the temperature which is measured at
the heat sink. Then fan switches on, when a certain temperature is reached
and switches to a higher speed when the second temperature limit is
reached.
Start lower speed 45°C
Start higher speed 55°C
Temperature control of cooking zones
The residual heat indicator contributes to the protection of the user. The
residual heat indication switches on with an „H" as soon as a certain
temperature underneath the glass ceramic is reached.
And it switches off again as soon as the temperature decreases under a
certain level.
Threshold „ON" residual heat indicator 65°C + 5K
Threshold „OFF" residual heat indicator 60°C – 5K