5.3
C
HARGER FUNCTION
Model
Input
Voltage
Frequency
Input current consumption 230/115VAC
Power factor
Efficiency
Input fuses F1/F2
Output
Number of outputs
Total rated current (+/-7%) / rated power
charging curve
Battery type
Regulated and filtered output voltage
Regulation tolerance before output Mosfet
splitter and fuse
Peak-to-peak ripple and noise
Automotive output fuses mounted in series
in minus pole -BAT
Electrical protections
Options
Temperature probe
Communication
,
UEYPO 12V-16A, 12V-25A
MODEL
12V-16A
1,1A/2,2A
T6,3A/250V – SCHURTER MST 250 Réf. 0034.6623
3 (including 1 for the engine battery): BAT E, +BAT 1 and +BAT 2 (integrated Mosfet
Each bank can be used individually and deliver the rated current
16A/228W
IU or IUoU through internal dip switches (Boost, Absorption, Floating and Refresh –
Lead sealed as factory setting – Other choices through internal setting:
1 x 20A/32V (F500)
- Against leaking input surges by VDR rupture (voltage dependent resistor) - not
covered by warranty
- Against output polarity reversals by fuse rupture
- Against output short-circuits and surges
- Against abnormal overheating by cutting off the charger (internal temperature
probe – Automatic restart)
12V-40A
AND
12V-25A
From 90 to 265VCA single phase automatic
From 47 to 65Hz automatic
1,7A/3,4A
90% typical
(F101)
splitter), 1 –BAT
25A/356W
factory setting)
gel, AGM, Calcium Lead, Stabilized power supply, etc.
See selection wheel setting table
< 2% (at rated conditions)
< 2% (at rated conditions)
1 x 30A/32V (F500)
Output voltage compensation : -18mV/°C
CAN BUS interface
12V-40A
2,7A/5,6A
1
T15A/250V – 6,3x32
(101)
40A/570W
2 x 25A/32V (F500, F501)
41