5
TECHNICAL SPECIFICATIONS
5.1
E
NVIRONMENT
Model
Environment
Operating temperature
Cooling
Relative humidity
Storage temperature
Casing
Material
Paintwork
Dimensions (length, height, depth) / Weight
Fixing centre distances
Fixing screw (wall)
Protection factor
Board protection
Standards
CE/EMC marking
CE/safety marking
5.2
AC
DISTRIBUTION
Model
Input
Voltage
Frequency
Current intensity 230/115VAC
Input circuit breaker
Output
Voltage
frequency
Number of outputs
Output current
Output circuit breaker
(1)
Consult CRISTEC for 115VCA 60Hz applications.
,
,
CASING
NORMS
Rated conditions : from - 20°C to + 40°C
Natural cooling
Up to 70% (95% with no condensation)
-20°C to +70°C
Casing comprises :
389 x 214,5 x 137,2 mm
4 M5 round screws
IP20
Protected with water-repellent varnish (marine environment)
NF EN61000-6-1, NF EN61000-6-2
NF EN60950
115
12V-16A
steel cover and steel frame
aluminum heatsink
Frame satin slate gray RAL7015
Cover satin gray RAL7047
389 x 214,5 x 137,2 mm
4,4Kg
375 x 158 mm
12V-16A
(1)
/ 230 +/-15% single-phase. The earth-leak circuit breaker test
button does not operate for voltages below 180VCA.
< 16A (depending on output's consumption)
16A bipolar earth-leak circuit breaker
2,3 or 4 depending on model
10A per output max
Added max total =16A
Circuit breaker Ph+N, 10A
Number : 2, 3 or 4 depending on model
12V-25A
4,4Kg
375 x 158 mm
422 x 180 mm
12V-25A
(1)
50/60Hz
= input voltage
= input frequency
12V-40A
439 x 214,5 x 134,2
6Kg
12V-40A
40