3.2.1 Cable lead-in
The mains cable lead -in is routed through a supplied WAGO female plug reference 770-103.
The AC connections are made through cable bushings.
The battery cable lead-in is routed through cable bushings.
When connecting or disconnecting a cable, the unit's power supply must be off and the batteries electrically insulated
from the charger.
The references for additional supplies required for the appliance to operate efficiently are provided in the following
paragraphs: failure to comply with these provisions renders the warranty null and void.
3.2.2 Cable from the public AC power supply network or generator
Disconnect AC network before any wiring and connecting of the connector.
All YPOWER short power units can operate automatically and equally on single phase 115
networks.
Note: The earth-leak circuit breaker test button does not operate for voltages below 185VAC.
(1)
Consult CRISTEC for 115VCA 60Hz applications.
Generators
The CRISTEC shore power units are designed to operate from a generator.
Be careful: In some cases, the generators can produce high over voltages, in particular during start-up
phase. Before connecting the shore power units, please check its compatibility with the characteristics
of the generator: power, voltage, overvoltage, frequency, current, etc.
It's highly advised to disconnect the shore power units from the AC network during the generator
starting phase.
Any damage to the shore power unit due to a voltage surge will be excluded from the warranty.
The power cable must be connected to female plug:
:
Earth
N:
Neutral
L:
Phase
The cross-section of AC power cables must be at least equal to 4 mm ².
The type of cable (H07-VK, MX, etc.) should be defined by the installer according to the application type and the
enforceable standards.
The PE conductor (commonly called "earth", the green and yellow wire) of the AC source must be connected to the
terminal provided for the purpose, and this must be done before connecting any other terminals.
(1)
(1)
/230VCA – 50/60Hz