3.2.6 Precautions regarding electromagnetic disturbance generated by the appliance

We recommend a minimum distance of 2m between shore power unit and any potentially sensitive equipment.
Use shielded cables for all the connections (*). The shielding should be earthed at both the transmitting and the
receiving ends.
Keep cable length and shielding connections to a minimum.
Route cables as close as possible to conductive parts ("loose" cables or loops should be avoided – cables should be
placed against the hull or walls).
Keep power cables separate from battery cables.
Keep power cables separate from control cables (at least 200mm).
The cables should only supply power to this appliance; any deviation to power another appliance is prohibited.
(
)
*
This is a recommendation for installation rather than an obligation. The installing electrician should decide whether
or not to use shielded cable depending on the EMC environment.

3.2.7 Cabling principle

Typical installation
Other types of cabling
See appendix 5.