Precautions regarding overheating of the appliance
This appliance is designed to be mounted on a vertical
wall or partition as indicated herein.
It is imperative that there be a gap of 150mm around
the shore-power unit. The installer must ensure that
the temperature of the air at the input is lower than
40°C in extreme operating conditions.
Measures should also be taken to allow for the
evacuation of hot air on either side of the shore-
power unit.
It's strictly forbidden to put any device on or against
the shore-power unit.
The shore-power unit must not be installed near a
heat source; it should be installed in a well-ventilated
area. The shore-power unit's air inlets and outlets
must not be obstructed.
Precautions regarding dust, seepage and falling
water
The shore-power unit should be located so as to
prevent penetration of damp, liquid, salt and dust, any
of which could cause irreparable damage to the
equipment and be potentially hazardous for the user.
The appliance should be installed in a dry and well-
ventilated place.