Accessories - Novy 680/15 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Finishing of the hood
5
• When necessary you can fortify the front of cabinet. Make sure the hood is well aligned with the lower part of the
cabinet.
Install the exhaust duct
The motor outlet has a diameter of 150 mm. It is recommended to connect an exhaust duct with a diameter of 150 mm to
this. A reducer is supplied with the hood. Only mount the reducer when using an exhaust duct with a diameter of 125 mm.
For optimum performance of the hood it is important to pay attention to the following points.
Circular ducts:
• Use smooth, non-flammable pipes with an internal diameter that is equal to the external diameter of the connection-
nozzle of the hood. Maximally extend flexible ducts and cut them to size.
• Do not reduce the exhaust diameter. This will lower the capacity and raise the noise level.
• When connecting to a short exhaust duct, it may be required to mount a non-return valve in the duct to avoid wind-
blowing in.
• Use a hose clamp or aluminum tape for airtight connections.
• In case of an exhaust pipe through the wall, use a wall vent.
Flat duct:
• Use flat duct with rounded corners and with air deflectors. Available at Novy.
General information:
• Make the duct as short as possible and with as few as possible bends to the outside.
• Avoid square bends. Use rounded bends for proper air conduction.
• In case of an exhaust pipe through the outside wall passing a cavity wall, make sure that the exhaust duct fully bridges
the cavity and slightly declines to the outside.
• In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
• Never connect to a flue duct.
• Make sure that sufficient air is supplied. Fresh air can be supplied by slightly opening a window or an outside door or
by installing an inlet grate.

ACCESSORIES

Recirculation
In case of recirculation Novy provides charcoal filters. The manual supplied with the recirculation kit includes the mounting
and user instructions.
Various accessories
- Clamp Ø60-215 mm
- Aluminium tape (per 50 m)
- Aluminium wall vent for outlet Ø150mm
- One-way valve Ø150mm
- Stainless steel cleaner
906291
906292
906178
906269
906060
EN 10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

686/15Fusion 680Fusion 686

Table des Matières