Degrease the attachment lip A of the hood using the supplied degreasing cloth (661057). Then attach the decorative
6
strip by pushing it onto the extractor hood.
You can choose to replace the front frame with a frame in the shape or colour of the kitchen. To replace the front
7
frame the drawer must be slid out. Then remove the screws on the left and right sides. The front frame can now be
removed from the extractor hood.
Unscrew only the mounting bracket of the front frame and place this on the new front frame. Then fit the new front
8
frame to the extractor hood.
Install the exhaust duct
The motor outlet has a diameter of 150 mm. It is recommended to connect an exhaust duct with a diameter of 150 mm
to this.
For optimum performance of the extractor hood it is important to pay attention to the points given below during the instal-
lation.
When using a round exhaust duct:
• Use smooth, non-flammable pipes with an internal diameter that is equal to the external diameter of the connection
nozzle of the hood. Maximally extend flexible ducts and cut them to size.
• Do not reduce the exhaust diameter. This will reduce the capacity and increase the noise level.
• When connecting to a short exhaust duct, it may be required to mount a non-return valve to prevent the wind from
blowing in.
• Use a hose clamp or aluminium tape for airtight connections.
• In case of an exhaust pipe through the outside wall, use the outside wall grate.
When using a flat exhaust duct:
• Use flat ducts with rounded corners and air conductors in the bends. These ducts are to be obtained through Novy.
General:
• Make the duct as short as possible and with as few as possible bends to the outside.
• Avoid square bends. Use rounded bends for proper air conduction.
• If an exhaust pipe through the outside wall passes a cavity wall, make sure that the exhaust duct fully bridges the cavity
and slightly declines to the outside.
• In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
• Never connect the exhaust to a flue duct.
• Make sure that sufficient air is supplied. Fresh air can be supplied by slightly opening a window or an outside door or
by installing an inlet grate.
• Use the delivered white insulating tape for an airtight seal (801-006).

ACCESSORIES

Recirculation
If you opt for recycling, Novy offers a monoblock recirculation filter that is positioned in the extractor hood. The manual
supplied with the recirculation kit includes the mounting and user instructions.
Other accessories
Article numbers of various accessories:
- Hose clamp adjustment range Ø60-135 mm
- Hose clamp adjustment range Ø60-215 mm
- Aluminium tape roll - 50 m
- Aluminium blind external wall grille Ø125 mm
- Aluminium blind external wall grille Ø150 mm
- Non-return valve Ø125 mm
- Non-return valve Ø150 mm
- Cleaning agent for stainless steel: maintenance agent for cleaning the stainless steel
Changes and misprints reserved, June 2015