Controls And Indicators; Inspections Prior To Starting; Starting And Stopping; Emergency Stopping - Nilfisk VHS120 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Controls and indicators

Figure 5
1.
Main
motor
Start/Stop
Use the button to start/stop the first motor. If the indicator
is lit, the main motor is ON.
2.
Second motor Start/Stop indicator and button
Use the button to start/stop the second motor. If the
indicator is lit, the second motor is ON.
3.
Vacuum gauge
4.
Manual filter shaker lever

Inspections prior to starting

Figure 6
1.
Vacuum inlet
Before starting, check that:
The filters are installed.
The closing band is properly tightened.
The vacuum hose and tools have been correctly fitted into
the vacuum inlet (1).
In case of liquid application, the liquid mechanical stop is
properly installed inside the liquid container:
The bag or safety container is installed, if applicable.
CAUTION!
Do not use the device if the filters are faulty.

Starting and stopping

Figure 5
CAUTION!
Before starting the machine, lock the castor brakes
Turn the button (1) to "I" position to start the first motor
(indicator light on).
Turn the button (2) to "I" position to start the second motor
(indicator light on).
Turn the button (1) to "0" position to stop the first motor
(indicator light off).
Turn the button (2) to "0" position to stop the second motor
(indicator light off).
Machines equipped with system for vacuuming
liquids
When the container is full, the liquid mechanical stop turns
off the vacuuming; the vacuum unit remains on.
Do not let the vacuum unit running, after the liquid stop
has been activated. Turn it off with the relevant switch.
indicator
and
button
9

Emergency stopping

Figure 5
Turn the buttons (1 and 2) to "0" position. The vacuum cleaner
stops.
CAUTION!
The motors and internal components of the vacuum
cleaner will still be electrically powered.

Operation

Figure 7
Vacuum gauge (2): green zone (3), red zone (1)
When using the machine, check the flow control:
when the machine is operating, the pointer of the vacuum
gauge must remain in the green zone (3) to ensure that
the speed of the intake air does not drop below the safety
value of 20 m/sec;
If the pointer is in the red zone (1) it means that the speed
of the air in the vacuum hose is less than 20 m/s, and that
the machine is not operating in optimal conditions. Shake
or replace the filter.
during normal operation conditions, close the vacuum
hose, the pointer of the vacuum gauge must switch from
the green zone (3) to the red zone (1).
CAUTION!
The air speed in the vacuum hose must not be less than
20 m/s.
This state is shown by the green indicator of the primary
filter.
CAUTION!
All machines can be used only with hoses whose
diameters comply with the specifications in the
"Technical Data" table.
CAUTION!
Consult the "Troubleshooting" chapter if faults occur.
At the end of a cleaning session
Turn off the machine and remove the plug from the socket.
Wind up the connection cable.
Empty the container and clean the machine as described
in the "Maintenance, cleaning and decontamination"
paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Store the machine in a dry place, out of reach of
unauthorised people.
Lock the castor brakes.
During transport and when not using the machine, close
the vacuum inlet with the relevant plug (if equipped).
VHS120
I
GB
F
D
E
C438

Publicité

Table des Matières
loading

Table des Matières