Technical specifications - Dimensions
Technical specifications
Parameter
Units
Voltage / frequency
Volt / Hz
kW
Installed power
HP
Weight
kg
Noise level
dB(A)
Protection
IP
Insulation
class
Shaving capacity
L
Liquid capacity
L
Max vacuum
mm H
Max air flow rate
L/m'
Emptying pump
L/m'
capacity
[ NOTE ]
■
Storage conditions:
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
■
Operating conditions:
Maximum altitude: 800 m
(Up to 2,000 m with reduced performances)
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
Dimensions
Figure 3
Model
A (mm)
B (mm)
C (mm)
01/2015
ECO OIL
ECO OIL
13
22
230/50
400/50
1.3
2.2
1.8
3
120
135
70
71
43
55
B
F
30
30
180
180
O
3,200
3,300
2
2,675
5,100
80
80
ECO OIL 13
ECO OIL 22
670
1050
1500
Controls and indicators
A - Green suction motor start button.
B - Red suction motor stop button.
C - Emptying pump start switch
D - Main switch
Inspection prior to starting
Prior to starting, check that:
■
All latches are tightly locked.
■
The vacuum hose and tools have been correctly fitted
onto the inlet "F" (fig. 5).
■
Do not use the vacuum cleaner if the filter is faulty.
Starting up
■
Lock the castor brakes before starting the vacuum
cleaner "E" (fig. 6).
■
Push the button "A" - fig. 4.
For three-phase motor only: if the vacuum cleaner has
been working and then stops or if the vacuum cleaner motor
turns in the wrong direction, turn it off, remove the plug from
the power socket and have the power cables inverted by a
specialised electrician.
Stopping - Emergency stopping
Push the button "B" (fig. 4).
-5-
ECO OIL 13/22
Figure 4
GB
C77