Protection Des Appareils Via Le Lon; Mise À Jour Du Micro Logiciel - Aquametro CALEC ST' 11741 En Complément Des Instructions De Montage Et D'utilisation

Lon tp/ft-10 interface
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

No. /
NV-Variable
Data
Obj.
Unit
20 / 3
nvoH1Mem1
float / **)
[Wh],[L],[g]
21 / 3
nvoRegH2Mem1
Structur / *)
22 / 3
nvoH2Mem1
float / **)
[Wh],[L],[g]
23 / 3
nvoRegH3Mem1
Structur / *)
24 / 3
nvoH3Mem1
float / **)
[Wh],[L],[g]
Utility Data Logger Register #2110: "Freeze-Memory"
1 / 4
nvoRegEnFrz
Structur
1 / 4
nvoRegEnPosFrz
Structur
1 / 4
nvoRegH1Frz
Structur
8 / 4
nvoRegTimeFrz
Structur / -
10 / 4
nviDoFrz
Structur / -
11 / 4
nvoEnFrz
float / [Wh]
11 / 4
nvoEnPosFrz
float / [Wh]
12 / 4
nvoRegVolFrz
Structur
12 / 4
nvoRegVolPosFrz
Structur
13 / 4
nvoVolFrz
float / [L]
13 / 4
nvoVolPosFrz
float / [L]
14 / 4
nvoRegEnNegFrz
Structur
15 / 4
nvoEnNegFrz
float / [Wh]
16 / 4
nvoRegVolNegFrz
Structur
17 / 4
nvoVolNegFrz
float / [L]
18 / 4
nvoRegMassFrz
Structur / *)
19 / 4
nvoMassFrz
float / [g]
20 / 4
nvoH1Frz
float / **)
[Wh],[L],[g]
21 / 4
nvoRegH2Frz
Structur / *)
22 / 4
nvoH2Frz
float / **)
[Wh],[L],[g]
23 / 4
nvoRegH3Frz
Structur / *)
24 / 4
nvoH3Frz
float / **)
[Wh],[L],[g]
Open Loop Actuator Object #3: "Relais 1"
1 / 5
nviSetRelais1
Structur / -
Open Loop Actuator Object #3: "Relais 2"
1 / 6
nviSetRelais2
Structur / -
*)
Le type de données 'SNVT_reg_val_ts' ne contient pas d'unité de masse. En cas d'utilisation comme registre massique, 'sans unité' est identique [t].
** ) Les compteurs auxiliaires comme variable float sont transférés sans unité comme 'SNVT_count_f'. Les valeurs de compteur sont :
• Médium Energie en watts/heure [Wh]
• Médium Volumen en litres [L]
• Médium Masse en grammes [g]
• Médium sans unité également transmis sans unité.

Protection des appareils via le LON

Pour des raisons de technique d'étalonnage, le CALEC
mécaniques. Le protocole LonTalk ne présente en revanche aucun mécanisme de protection comparable. C'est pourquoi on a volontaire-
ment renoncé à la possibilité d'éditer des paramètres étalon nables via le réseau LON.
La configuration de l'interface LON est paramétrable conformément au protocole LonTalk.
Mise à jour du micro logiciel
Le micro logiciel Neuron FT5000 peut être mis à jour à l'aide des outils réseau appropriés (par ex., LonMaker™).
SNVT
Range of values
Obj.
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_time_stamp
0..3000 J. / 0..59 Min.
SNVT_state
Bit 0: "1": Freeze
SNVT_elec_whr_f
0..1E38 Wh
SNVT_elec_whr_f
0..1E38 Wh
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_vol_f
0..1E38 L
SNVT_vol_f
0..1E38 L
SNVT_reg_val_ts
99999999, unit, time...
SNVT_elec_whr_f
0..1E38 Wh
SNVT_reg_val_ts
99999999, unit, time...
SNVT_vol_f
0..1E38 L
SNVT_reg_val_ts
99999999, [ ], time...
unit 'NONE' = [t]
SNVT_mass_f
0..1E38 g
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_state
Bit 0: "1" Relais activ
SNVT_state
Bit 0: "1" Relais activ
®
ST applique quatre niveaux de protection, qui sont protégés par des plombages
Designation
Memory1 submeter #1
Memory1 submeter reg. #2
x
Memory1 submeter #2
x
Memory1 submeter reg. #3
x
Memory1 submeter #3
x
Freeze energy register
x
Freeze energy pos.register
Submeter register #1
Freeze date / time
x
Freeze command
x
Freeze energy value #1
x
Freeze energy pos. value #1
Freeze volume reg. #1
x
Freeze volume pos. Reg. #1
Freeze volume value #1
x
Freeze volume pos. value #1
Freeze energy neg. register
Freeze energy neg. value #1
Freeze volume neg. reg. #1
Freeze volume neg. value #1
Freeze mass reg. #1
Freeze mass value #1
Freeze submeter #1
Freeze submeter reg. #2
x
Freeze submeter #2
x
Freeze submeter reg. #3
x
Freeze submeter #3
x
Set relay 1
x
Set relay 2
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
29

Publicité

Table des Matières
loading

Table des Matières