No. /
NV-Variable
Data
Obj.
Unit
20 / 3
nvoH1Mem1
float / **)
[Wh],[L],[g]
21 / 3
nvoRegH2Mem1
Structur / *)
22 / 3
nvoH2Mem1
float / **)
[Wh],[L],[g]
23 / 3
nvoRegH3Mem1
Structur / *)
24 / 3
nvoH3Mem1
float / **)
[Wh],[L],[g]
Utility Data Logger Register #2110: "Freeze-Memory"
1 / 4
nvoRegEnFrz
Structur
1 / 4
nvoRegEnPosFrz
Structur
1 / 4
nvoRegH1Frz
Structur
8 / 4
nvoRegTimeFrz
Structur / -
10 / 4
nviDoFrz
Structur / -
11 / 4
nvoEnFrz
float / [Wh]
11 / 4
nvoEnPosFrz
float / [Wh]
12 / 4
nvoRegVolFrz
Structur
12 / 4
nvoRegVolPosFrz
Structur
13 / 4
nvoVolFrz
float / [L]
13 / 4
nvoVolPosFrz
float / [L]
14 / 4
nvoRegEnNegFrz
Structur
15 / 4
nvoEnNegFrz
float / [Wh]
16 / 4
nvoRegVolNegFrz
Structur
17 / 4
nvoVolNegFrz
float / [L]
18 / 4
nvoRegMassFrz
Structur / *)
19 / 4
nvoMassFrz
float / [g]
20 / 4
nvoH1Frz
float / **)
[Wh],[L],[g]
21 / 4
nvoRegH2Frz
Structur / *)
22 / 4
nvoH2Frz
float / **)
[Wh],[L],[g]
23 / 4
nvoRegH3Frz
Structur / *)
24 / 4
nvoH3Frz
float / **)
[Wh],[L],[g]
Open Loop Actuator Object #3: "Relais 1"
1 / 5
nviSetRelais1
Structur / -
Open Loop Actuator Object #3: "Relais 2"
1 / 6
nviSetRelais2
Structur / -
*)
The data type: 'SNVT_reg_val_ts' contains no unit for mass. When using as a mass register 'dimensionless' equals [t].
** ) The submeter as a float variable is transmitted as 'SNVT_count_f' and is dimensionless. The counter values are also transmitted for:
• medium energy in watt-hours [Wh]
• medium volume in liters [l]
• medium mass in gram [g]
• medium without unit.
Device protection on LON side
For verification purposes, the CALEC
no such similar protection. Editing of verification parameters via the LON network was therefore dispensed with.
Configuration of the LON interface is carried out using the LonTalk protocol.
Firmware update
The firmware of the Neuron can be updated using appropriate network tools (e.g. LonMaker™).
SNVT
Range of values
Obj.
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_time_stamp
0..3000 J. / 0..59 Min.
SNVT_state
Bit 0: "1": Freeze
SNVT_elec_whr_f
0..1E38 Wh
SNVT_elec_whr_f
0..1E38 Wh
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_vol_f
0..1E38 L
SNVT_vol_f
0..1E38 L
SNVT_reg_val_ts
99999999, unit, time...
SNVT_elec_whr_f
0..1E38 Wh
SNVT_reg_val_ts
99999999, unit, time...
SNVT_vol_f
0..1E38 L
SNVT_reg_val_ts
99999999, [ ], time...
unit 'NONE' = [t]
SNVT_mass_f
0..1E38 g
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_state
Bit 0: "1" Relais activ
SNVT_state
Bit 0: "1" Relais activ
®
ST has 4 levels of protection and which have a mechanical seal. The LonTalk protocol, however, has
Designation
Memory1 submeter #1
Memory1 submeter reg. #2
x
Memory1 submeter #2
x
Memory1 submeter reg. #3
x
Memory1 submeter #3
x
Freeze energy register
x
Freeze energy pos.register
Submeter register #1
Freeze date / time
x
Freeze command
x
Freeze energy value #1
x
Freeze energy pos. value #1
Freeze volume reg. #1
x
Freeze volume pos. Reg. #1
Freeze volume value #1
x
Freeze volume pos. value #1
Freeze energy neg. register
Freeze energy neg. value #1
Freeze volume neg. reg. #1
Freeze volume neg. value #1
Freeze mass reg. #1
Freeze mass value #1
Freeze submeter #1
Freeze submeter reg. #2
x
Freeze submeter #2
x
Freeze submeter reg. #3
x
Freeze submeter #3
x
Set relay 1
x
Set relay 2
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
19