No. /
NV-Variable
Data
Obj.
Unit
20 / 3
nvoH1Mem1
float / **)
[Wh],[L],[g]
21 / 3
nvoRegH2Mem1
Structur / *)
22 / 3
nvoH2Mem1
float / **)
[Wh],[L],[g]
23 / 3
nvoRegH3Mem1
Structur / *)
24 / 3
nvoH3Mem1
float / **)
[Wh],[L],[g]
Utility Data Logger Register #2110: "Freeze-Memory"
1 / 4
nvoRegEnFrz
Structur
1 / 4
nvoRegEnPosFrz
Structur
1 / 4
nvoRegH1Frz
Structur
8 / 4
nvoRegTimeFrz
Structur / -
10 / 4
nviDoFrz
Structur / -
11 / 4
nvoEnFrz
float / [Wh]
11 / 4
nvoEnPosFrz
float / [Wh]
12 / 4
nvoRegVolFrz
Structur
12 / 4
nvoRegVolPosFrz
Structur
13 / 4
nvoVolFrz
float / [L]
13 / 4
nvoVolPosFrz
float / [L]
14 / 4
nvoRegEnNegFrz
Structur
15 / 4
nvoEnNegFrz
float / [Wh]
16 / 4
nvoRegVolNegFrz
Structur
17 / 4
nvoVolNegFrz
float / [L]
18 / 4
nvoRegMassFrz
Structur / *)
19 / 4
nvoMassFrz
float / [g]
20 / 4
nvoH1Frz
float / **)
[Wh],[L],[g]
21 / 4
nvoRegH2Frz
Structur / *)
22 / 4
nvoH2Frz
float / **)
[Wh],[L],[g]
23 / 4
nvoRegH3Frz
Structur / *)
24 / 4
nvoH3Frz
float / **)
[Wh],[L],[g]
Open Loop Actuator Object #3: "Relais 1"
1 / 5
nviSetRelais1
Structur / -
Open Loop Actuator Object #3: "Relais 2"
1 / 6
nviSetRelais2
Structur / -
*)
Der Datentyp: ' SNVT_reg_val_ts' enthält keine Einheit für Masse. Bei Verwendung als Masse-Register ist 'einheitenlos' gleich [t].
** ) Die Hilfszähler als float-Variable werden einheitenlos als 'SNVT_count _f' übertragen. Die Counterwerte werden bei:
• Medium Energie in Watt-Stunden [Wh]
• Medium Volumen in Liter [L]
• Medium Masse in Gramm [g]
• Medium ohne Einheit auch einheitenlos übertragen.
LON-seitiger Geräte-Schutz
®
Der CALEC
ST kennt aus eichtechnischen Gründen 4 Schutzgradstufen, die durch mechanische Siegel geschützt sind. Das LonTalk-Pro-
tokoll kennt hingegen keinen vergleichbaren Schutzmechanismus. Deshalb wurde auf die Editierbarkeit eichrelevanter Parameter über das
LON-Netzwerk bewusst verzichtet.
Die Konfigurierung der LON-Schnittstelle ist gemäss LonTalk-Protokoll parametrierbar.
Firmware-Update
Die Firmware des Neurons FT5000 ist mit Hilfe geeigneter Netzwerk-Tools (z.B. LonMaker™) update-fähig.
SNVT
Range of values
Obj.
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_time_stamp
0..3000 J. / 0..59 Min.
SNVT_state
Bit 0: "1": Freeze
SNVT_elec_whr_f
0..1E38 Wh
SNVT_elec_whr_f
0..1E38 Wh
SNVT_reg_val_ts
99999999, unit, time...
SNVT_reg_val_ts
99999999, unit, time...
SNVT_vol_f
0..1E38 L
SNVT_vol_f
0..1E38 L
SNVT_reg_val_ts
99999999, unit, time...
SNVT_elec_whr_f
0..1E38 Wh
SNVT_reg_val_ts
99999999, unit, time...
SNVT_vol_f
0..1E38 L
SNVT_reg_val_ts
99999999, [ ], time...
unit 'NONE' = [t]
SNVT_mass_f
0..1E38 g
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_reg_val_ts
99999999, unit, time...
SNVT_count_f
0..1E38 Counts in
Wh or L or g
SNVT_state
Bit 0: "1" Relais activ
SNVT_state
Bit 0: "1" Relais activ
Designation
Memory1 submeter #1
Memory1 submeter reg. #2
x
Memory1 submeter #2
x
Memory1 submeter reg. #3
x
Memory1 submeter #3
x
Freeze energy register
x
Freeze energy pos.register
Submeter register #1
Freeze date / time
x
Freeze command
x
Freeze energy value #1
x
Freeze energy pos. value #1
Freeze volume reg. #1
x
Freeze volume pos. Reg. #1
Freeze volume value #1
x
Freeze volume pos. value #1
Freeze energy neg. register
Freeze energy neg. value #1
Freeze volume neg. reg. #1
Freeze volume neg. value #1
Freeze mass reg. #1
Freeze mass value #1
Freeze submeter #1
Freeze submeter reg. #2
x
Freeze submeter #2
x
Freeze submeter reg. #3
x
Freeze submeter #3
x
Set relay 1
x
Set relay 2
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
9