Symptom
• The unit gives out a beeping sound.
• When the unit starts up or runs,
the display shows E9 (compressor
protection). The unit goes off
automatically,
showing E9 until the unit has a
slant of less than 45º.
• Water is entering the cabin or is
filtering in from outside.
• The equipment works but does not
cool.
* Suitable machinery must be used whenever it is necessary to extract or introduce the
circuit gas load, respecting the environment at all times.
with
the
display
Air conditioning for vehicles
• Belt poorly connected or inverted in the
keypad.
• Unit slant 45º or over.
• Valves or wastewater pipes obstructed.
• EPDM seal poorly attached or defective.
• The cabling outputs which protrude from
the lower cover of the blower and coil cabin
are not properly sealed.
• Too much or too little load in the circuits.
• Electro wire clamp inverted.
• Dirt in the capacitor.
• Electro defective.
• Blockage in the circuit (may be due to
excess oil).
20