2) AUTOMATIC mode
• In this mode, the LED display shows "AUTOMATIC MODE".
• The pump starts to run. If pressure built up in the pressure line and no flow (such as the
valve is closed), the pump will stop automatically in 10 seconds.
• If no pressure built up and no flow, the pump will run for 60 seconds, then pause for 20
seconds. After 3 cycles, the pump will stop and display "CHECK WATER". When the user
press "SET" button, the pump will repeat 3 more cycles and enter STOP mode.
• Otherwise, the pump will run continuously.
3) TIME mode
• Press "MODE" button for several times until the "TIME MODE" is displayed.
• After entering in the TIME mode, the pump pauses for 2 seconds.
• User can set the current time, start time and stop time to control the pump.
• "TIME NOW" = current time
• "TIME ON" = start time
• "TIME OFF" = stop time
• When setting time, press "SET" button for "+", while press "MODE" button for "-".
• Press "MODE" button to exit.
• Press "SET" button to go to next step.
• Press "CHECK" button to save and go to next step.
• The LED display shows "TIME NOT SET" if both start time and stop time are the same.
User can press "SET" button to set the time again.
• When setting is done, user can check time setting by pressing "CHECK" button.
4) ALWAYS ON mode
• In this mode, the LED display flashes "ALWAYS ON" and "NOT RECOMMENDED".
• Press the "MODE" button to exit and return to STOP mode.
VI. MAINTENANCE AND STORAGE
WARNING!
Before any intervention on product, ensure that power is set to the "OFF" position
and disconnect from main power source.
Reminder: In order to maintain the machine in good working condition, carry out regular
maintenance of the machine after each use and before storage. Any breach or inadequate
maintenance reduces the life of the machine and increases the risk of breakdowns and accidents.
6.1- Cleaning
• Clean the pump exterior with a dry clean cloth. Do not use water or detergent for cleaning.
• Before extended periods of inactivity or winter, the pump should be internally flushed with
water, emptied completely (using the draing port) and stored in dry environment.
• Always keep the ventilation holes clean.
6.2- Storage
• Clean the product before storage.
• Keep product, instruction manual and accessories (if any) in the original packaging.
• Store the product in a clean environment, where is not freezing or too hot (exceed 50 ̊ C ).
• Keep out of reach of children (e.g. lock it up).