ELGA-TB-G/-KF/-RF
5.1.3
Mount accessories
To protect the end positions against uncontrolled excess travel:
• Check the necessity of proximity sensors (hardware limit switches).
If proximity sensors are used as limit switches:
• Preferably use proximity sensors with normally-closed function.
This protects against excess travel beyond the end position, if the proximity sensor cable is broken.
If proximity switches are used as reference switches:
• Use proximity sensors that correspond to the input of the controller being used.
• Use proximity sensors with switch lug (è Assembly instructions of the accessory).
Mounting options of the proximity sensor
1)2)
in the grooves
1
Switch lug
2
Slot for proximity sensor
1) Not for ELGA-...-F1
2) When ELGA-TB-KF-M1/M2 securing the switch tab / proximity switch, this is only possible on the side opposite the measuring
system.
3) only with ELGA-...-F1
Fig. 13
• Avoid external influences from magnetic or ferritic parts in the vicinity of the proximity sensors (minimum
distance of 10 mm from the slot nuts).
• Use groove covers on all unused grooves to prevent contamination (è www.festo.com/catalogue).
Connection option for sealing air
• Connect sealing air. For this, remove threaded dowel
(5 è Fig. 14) from drive cover and connect up compressed
air / vacuum extraction. For additional protection, use other
sealing air connections. This is possible on both drive covers
on both sides.
36
with sensor bracket
1
2
1)
with mounting kit
3
1
3
Sensor bracket
4
Mounting kit
Fig. 14
Festo – ELGA-TB-G/-KF/-RF – 1512d English
3)
1
4
5

Publicité

loading

Ce manuel est également adapté pour:

Elga-tb-kfElga-tb-rf