CUCINOTTA – CUCINOTTA Forno
4.1.
FIRST-AID MEASURES
Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door.
b) Close the registers of combustion air
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
Seek immediate intervention of FIRE BRIGADE.
d)
DO NOT EXTINGUISH FIRE USING WATER JETS
When the fire has been extinguished, let the flue check by an expert to find possible cracks and permeable
points.
5.
FLUE
Essential requirements for a correct operation of the device:
•
the internal section must be preferably circular;
•
be thermally insulated and water-proof and produced with
materials suitable to resist to heat, combustion products and
possible condensates;
•
not be throttled and show a vertical arrangement with
deviations not greater than 45° ;
•
if already used, it must be clean;
•
observe the technical data of the instructions manual;
Should the flues have a square or rectangular section, internal edges
must be rounded with a radius not lower than 20 mm. For the
rectangular section, the maximum ratio between the sides must be ≤
1.5.
A too small section causes a decrease of the draught. It is suggested
a minimum height of 4 m.
The following features are forbidden and therefore they endanger
the good operation of the device: asbestos cement, galvanized steel,
rough and porous internal surfaces. Picture 3 gives some examples
of execution.
The minimum section must be 4 dm
for devices whose duct diameter is lower than 200 mm or 6.25
dm
(for example 25 x 25 cm) for devices with diameter greater
2
than 200 mm.
The draught created by the flue must be sufficient, but not excessive.
A too big flue section can feature a too big volume to be heated and
consequently cause difficulties in the operation of the device; to
avoid this, tube the flue along its whole height. A too small section
causes a decrease of the draught.
The flue must be properly spaced from any flammable materials
or fuels through a proper insulation or an air cavity.
It is forbidden to let plant piping or air feeding channels pass in the same flue. Moreover, it is forbidden to
create movable or fixed openings on the same for the connection of further other devices.
5.1.
CHIMNEY CAP POSITION
The draught of the flue depends also on the suitability of the chimney cap.
Therefore, if it is handicraft constructed, the output section must be more than twice as big as the internal
section of the flue.
7093101 – Rev.06 – EN
(for example 20 x 20 cm)
2
dust).
2
(1)
(2)
(3)
(4)
(1) AISI 316 steel flue with double
chamber
insulated
with
resistant to 400° C. Efficiency 100%
excellent.
(2)
Refractory
flue
insulated
chamber
and
coating
in
lightweight
Efficiency 100% excellent.
(3) Traditional clay flue square
section with cavities. Efficiency 80%
excellent.
(4) Avoid flues with rectangular
internal section whose ratio differs
from the drawing. Efficiency 40%
poor.
Picture 3
Max.
A+1/2A
A+1/2A
A
material
with
double
external
concrete.
19