boiler body.
During this phase, open all the bleed valves of the radiators to prevent the formation of air sacks, checking the outlet of water to avoid
unpleasant floodings.
The watertight test of the installation is performed with the pressure of expansion tank open.
The installation must always be full of water even when the thermo-product is not used. During winter season the non use has
to be faced by adding antifreeze substances.

3. FIRE-FIGHTING SAFETY MEASURES

When installing the product, the following safety measures must be observed:
a)
In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing components
flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with flammable structure (see
Picture 4 at page
55-A). All the minimum safety distances are shown on the product data plate and lower values must not
be used.
b)
in front of the furnace door, in the radiation area, there must be no flammable or heat-sensitive objects or material at a distance of
less than 100 cm. This distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed in
front of the whole component to protect.
c)
If the product is installed on a non totally refractory floor, one must foresee a fireproof background. The floors made of inflammable
material, such as moquette, parquet or cork etc., must be replaced by a layer of no-inflammable material, for instance ceramic,
stone, glass or steel etc. (dimensions according to the local regulations). The base must extend at least 50 cm at the front and at
least 30 cm at the sides, in addition to the opening of the loading door (see
d)
no flammable components (e.g. wall units) must be present above the product.
The Product must always operate exclusively with the ash drawer inserted. The solid combustion residues (ash) must be collected in a
sealed, fire resistant container. The Product must never be on in the presence of gaseous emissions or vapours (for example glue for
linoleum, petrol etc.). Never deposit flammable materials near the Product.
During combustion, thermal energy is released which leads to considerable heating of the surfaces, doors, handles, controls, glass parts,
the flue gas pipe and possibly the front part of the appliance. Avoid contact with these elements unless using suitable protective
clothing or accessories (heat resistant gloves, control devices).
Ensure children are aware of these dangers and keep them away from the furnace when it is on.
When using the wrong fuel or one which is too damp, due to deposits present in the flue, a flue fire is possible.

3.1. FIRST-AID MEASURES

Should any fire arise in the stack or in the flue:
a)
Close the feeding door.
b)
Close the registers of combustion air
c)
Extinguish the fire using carbon dioxide fire-fighting means (CO
d)
Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS.
When the flue does not burn any more please arrange an examination by a specialist in order to find possible cracks and permeable points.

4. DESCRIPTION

Definition: thermo-product according to EN 13240.
La Nordica thermoheating products are suitable for heating homes using a centralised heating system made up from radiators or heat
convectors entirely or partially replacing the traditional gas or diesel oil boiler.
The appliance is composed of painted and galvanised sheet steel and cast iron.
The fireplace is found inside the boiler, is built in 4 mm thick steel and is reinforced using welded nails. A swivelling, removable grid is found
inside the fireplace.
The water in the heating system circulates in the boiler, which absorbs the heat produced in the fireplace.
The ceramic glass window (resistant up to 700°C) of the door provides a lovely view of the burning flames and prevents sparks and smoke
from getting out.
Room heating takes place:
a) by radiation: the heat is radiated into the environment through the panoramic window and the hot external surfaces of the thermo-
product;
b) by conduction: radiators or heat convectors of the centralised system fed by hot water produced by the boiler.
The device is equipped with registers of primary and secondary air.
A- PRIMARY air register
With the primary air control
direction. The primary air is necessary for the combustion process. The ash drawer must be regularly emptied, so that the ash does not
18
TERMOROSSELLA PLUS DSA / FORNO DSA – TERMONICOLETTA DSA / FORNO DSA
(Picture 5 at page 55
- 1A) is adjusted the passage of air through the ash drawer and the grate in the fuel
Picture 4 at page 55
dust).
2
- B).