ShatterPro II Advanced Acoustic Sensor with
Pattern Recognition Technology Installation
Instructions
EN FR NL
1
4
EN: Installation Sheet
Description
ShatterPro II is an advanced version of the ShatterPro acoustic
glassbreak sensor. By processing over 30 frequency points
across the glass break frequency spectrum, ShatterPro II can
eliminate most common false alarm sounds, while providing
excellent glassbreak detection.
Use ShatterPro II for:
•
Perimeter loops for occupied or unoccupied buildings.
•
Most rooms including those with blinds and unlined
drapes.
•
Glass size of 1 x 2 ft. (0.3 x 0.6 m) or larger.
•
Glass thicknesses as follow:
- Plate Glass 3/32 to 1/4 in. (2.4 to 6.4 mm)
- Tempered Glass 1/8 to 1/4 in. (3.2 to 6.4 mm)
- Wired Glass 1/4 in. (6.4 mm)
- Laminated Glass 1/8 to 1/4 in. (3.2 to 6.4 mm)
© 2021 Carrier
2
25 ft. (7.5 m)
1 / 10
3
5
3.25 in.
8.3 cm
For best detection, avoid installing in:
•
Rooms with lined, insulating, or sound deadening drapes.
•
Rooms with closed wooden window shutters inside.
•
Ceilings higher than 15 ft. (4.5 m), if ceiling mounted.
Range of coverage
See Figure 4.
The coverage range is for worst-case breaks in worst-case
applications.
•
For ceiling mounted sensor: 25 ft. (7.5 m) radius of
coverage from sensor to the bottom of the glass; 20 ft.
(6.0m) from sensor to wall.
•
For wall mounted sensor: 25 ft. (7.5 m) of coverage to
farthest glass if mounted on opposite wall: 20 ft. (6.0 m)
coverage if mounted on adjoining wall.
•
If not using hand-held tester to verify range, reduce range
to 15 ft. (4.5 m) for windows with blinds and unlined
drapes.
•
Reduce coverage 50% for armor coated glass.
•
360° coverage pattern.
•
No sensitivity adjustment.
P/N 15652 (ML) • REV D • ISS 22JUL21
J3
NC
COM
TAMP
TAMP
NO
IC
0.88 in.
2.3 cm
®