sensor. The ShatterPro II typically does not trip to glass
breaks in the middle of a room. No burglar breaks glass in
the middle of a room, so such breaks are false alarms.
•
False alarms are most likely to occur when installed on a
24-hour loop, when installed in glass airlocks and glass
vestibule areas, when mounted above sinks, when used in
residential car garages, small utility rooms, stairwells,
small bathrooms, and in other small acoustically live
rooms, and rooms where multiple sounds can reflect and
eventually duplicate the glass break frequency pattern. For
glass break protection in such applications, use Carrier
Fire & Security shock sensors on windows or window
frames.
•
Do not install in humid rooms. No glassbreak sensor is
hermetically sealed. Excess moisture on the circuit board
can eventually cause a short and a false alarm.
•
Installing the ShatterPro II on 24-hour loops will increase
false alarms. The ShatterPro II is recommended for
perimeter loops and is designed to function without false
alarms in occupied areas. On a 24-hour loop which is
armed all day, all night every day, the false alarm
technology will be pushed to its limit since some sounds in
some conditions can duplicate the points on the glass
break pattern that the ShatterPro II detects. Install the
ShatterPro II on a perimeter loop which is armed
whenever the door and window contacts are armed. For
occupied area installations ShatterPro II false alarm
immunity is best in rooms with only moderate noise. For
24-hour occupied area protection, use Carrier Fire &
Security shock sensors.
•
ShatterPro II detects the shattering of glass. Like all
glassbreak sensors, it may not consistently detect cracks
in glass, or bullets which break though the glass or break
out of the glass. Glassbreak sensors should always be
backed up by interior protection.
•
Like all security sensors, the ShatterPro II should be
tested for proper operation at least once a year.
Wiring the sensor
See Figure 3.
Specifications
Housing material
Flame retardant ABS plastic
Operational voltage
9 to 16 V DC
Current draw
12 mA typical; 20 mA max
Relay output
Normally closed, open 4 seconds on alarm
10 Ω ± 5
On resistance
Off resistance
20 MΩ
Maximum loop rating
16 VDC, 50 mA
(relay or tamper loop)
Lightning suppression
400 W for 1 ms pulse
RF immunity
10 V/m, 80 MHz to 2.7 GHz
Microphone
Omni-directional electret
0 to 120°F (−18 to +55°C)
Temperature range
Color
White
Dimensions
See Figure 5
Wiring terminals
22-18 AWG
P/N 15652 (ML) • REV D • ISS 22JUL21
Ordering information
•
5812AES1-W: ShatterPro II, tamper, latch or non latch
LED/White
•
5709C-W: Hand held Tester, for testing effective
range/White
Note:
The products, materials, and specifications listed are
subject to change without notice as Carrier Fire & Security
strives for continuing product improvement.
Regulatory information (5812AES1-W only)
PLACED ON THE MARKET BY:
Manufacturer
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
European Union
Carrier Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see firesecurityproducts.com or
www.aritech.com.
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
recyclethis.info
Contact information
firesecurityproducts.com or www.aritech.com
3 / 10