SAFETY
Easy to use, safety of operation. The digital control panel controls the combined action
of the gas combustion fan, of the fuel loading, of the convection fan and of the control of
the room temperature. This control system grants the best combustion and functioning
conditions, reducing to the minimum the costs of functioning.
Maximum efficiency, minimum emissions. The large heat exchange surface, together
with an optimal control of the combustion air, provides an excellent yield of the fuel.
The release of the pellets dosed in the brazier, allows a complete combustion with low
emissions in the exhaust gas.
AUTOMATIC SAFETY FEATURES
Voltage drop. Even after a brief voltage drop, the unit stops and then restarts,
resuming the normal operation or restarting the automatic ignition phase,
without any security risk.
Shutdown due to overheating. In the event of abnormal heating of the appliance, the
security system intervenes and switch off the stove. The stove can then be switched on
again after leaving it to cool for at least 45 minutes. The persistence of this condition
must be verified by the service center or qualified personnel
Low-temperature shutdown. If the temperature of the appliance drops down to a certain
value, the unit turns off (for example the finishing of the fuel). This can also be switch
off can also accur if the lighting phase takes to much time. The stove must then be re
switched on again The persistence of this condition must be verified by the service center
or qualified personnel.
Electrical surge protection device. The device is protected against over current by a fuse
(see technical data) placed: one on the electronic board and one on the power socket.
For its replacement, contact Technical Service
RESIDUAL RISKS
The stove does not present itself potential risks, although it is complete with coatings in all its
parts, nevertheless the following residual risks may be present:
Risk of burns
Between the back of the stove and the smoke outlet (fume outlet pipe).
Contact with glass
Electric risk
Alimentation cable
Motors connection
Risk of fire
Opening the front door when the ashes are not extinguished.
Risk of cutting
Between the auger shaft and the material loading conduit; in the event of a jam, do not
carry out any material removal operations unless the stove has been switched off and the
power supply disconnected.