Hazardous Voltage.
Hazardous Voltage.
Will cause death or serious injury.
Will cause death or serious injury.
Turn off and lock out all power supplying this device before
Turn off and lock out all power supplying this device before
working on this device.
working on this device.
Replace all covers before power supplying this device is
Replace all covers before power supplying this device is
turned on.
turned on.
Dimensions for Welding or Screw-mounting the cover catch.
[ Dimensiones para soldar o atornillar el seguro de la puerta. ]
JG, LG
2
4 X Ø 9/32"
[ Ø7.0mm ]
"C"
Option:
[ Opción: ]
2 X Ø3/16"
[ 2 X Ø5mm ]
Tensión peligrosa.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Puede causar la muerte o lesiones graves.
Desenergice totalmente antes de instalar o darle servicio.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
energizar el interruptor.
"A"
Variable Dimension
Dimension "C"
"A"
[ Dimensión "C " ]
[ Dimensión "C " ]
[Dimensión variable
"A"]
Enclosure depth to
to mounting plate
mounting plate
JG/LG
[ Profundidad Caja ]
[ Profundidad Caja ]
"
"
7
-7.49
2.83" [ 71.9 mm ]
"
"
7.5
-7.99
2.70" [ 68.6 mm ]
"
"
8
-8.49
2.56" [ 65 mm ]
"
"
8.5
-8.99
2.42" [ 61.5 mm ]
"
"
9
-9.49
2.29" [ 58.2 mm ]
"
"
9.5
-9.99
2.15" [ 54.7 mm ]
"
"
10
-10.49
2.02" [ 51.3 mm ]
"
"
10.5
-10.99
1.88" [ 47.8 mm ]
"
"
11
-11.49
1.75" [ 44.5 mm ]
Customer supplied hardware for screw mounting option. Hardware must
maintain environmental integrity ( NEMA rating ) of the enclosure.
[ Material de montaje provisto por el cliente.
El material para montaje por tornillo debe mantener la integridad
ambiental ( grado NEMA) en la caja. ]
4 / 15
Tension dangereuse.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Danger de mort ou risque de blessures graves.
Couper l'alimentation de l'appareil et barrer avant de
Couper l'alimentation de l'appareil et barrer avant de
travailler.
travailler.
Remplacez touts les couverts avant que
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
l'approvisionnement de pouvoir soit alimenté.
.8" Min
[ 20 mm Min ]
Variable Dimension
Dimension "C"
"A"
[Dimensión variable
"A"]
Enclosure depth
JG/LG
"
"
11.5
-11.99
1.61" [ 40.6 mm ]
"
"
12
-12.49
1.48" [ 37.6 mm ]
"
"
12.5
-12.99
1.34" [ 34.03 mm ]
"
"
13
-13.49
1.2" [ 30.5 mm ]
"
"
13.5
-13.99
1.06" [ 26.9 mm ]
"
"
14
-14.49
0.93" [ 23.6 mm ]
"
"
14.5
-14.99
.79" [ 20.1 mm ]
"
"
15
-15.49
0.65" [ 16.5 mm ]
"
"
15.5
-15.99
.51" [ 13.0 mm ]
"
"
16
-16.49
0.38" [ 9.7 mm ]
Maintain minimum cable bend radius per
National Electrical Code.
[ Mantenga el radio mínimo en la
curvatura del cable dado por National
Electrical Code.]
.8" Min
[ 20 mm Min ]
[ Ø 5 mm ]
2X 8-32 X 3/8"
2X 8-32
Ø 3/16"
2X No. 8
806948A04