3.1.5
Safety cable
When hung or flown the fixture must be
secured by an additional hanging
accessory (such as a safety bond or
cable) of suitable length.
The combined weight of both the fixture
and the accessories must be considered
when choosing the load-bearing capability
of safety cable or bond.
Safety cables or bonds must be securely
attached to the back of the fixture and be
as short as possible, or rolled up as
necessary, to minimise travel distance
should the fixture be dislodged.
3.2
Electrical
3.2.1
LED source
Never touch or scratch LED surface.
See 5.1.4 LED cleaning procedure if cleaning is necessary.
3.2.2
Power
Voltage
90 264 V
Class 1 product. This luminaire must be earthed.
Must be connected directly to AC power. Do not connect to dimmer power
Automatic power detection
On the same breaker, maximum of: 14 units (230V) / 12 units (110V)
Daisy chain:
Power supply
Frequency
0.5 amps @ 230V
0.9 amps @ 120V
1.4 amps @ 90V
50/60 Hz
105 W (Max.120 W)
Standby mode: 15 W
- 7 -
Input power
Neutric PowerCon®
Input: ref. NAC3MPA
Output: ref.NAC3MPB
Maximum of:
14 units (230V)
12 units (110V)
EN
Connectors