n o
t o o L S
d M X
t S t F A n
t S t d S P
d M X
o F F
d I S P
1 _ 1 _ 0 1
U E r
0 0 0
t E M P
X X X Y Y Y
I n
C o n F I r
r E S E t
8 8 8 8 8 8
L o G
E E P r o M
L o G
o n t I M E
o n
d M H
Light intensity value if DMX not detected
H o L d
Value (-/+)
HOLD
OFF
MAN
Display
2 n
Value (-/+)
OFF 2m
ON
Software version
LED temperature
C °
DMX values (Display always ON)
Value (-/+)
XXX
YYY
Unit reset by pressing enter
Fan test
0
Y Y Y
Value (-/+)
0 31
Display test (all 7 segments = ON)
F A n
X X X X
L E D
U
X X X X
P S u
U
0 0 0
C °
L E d
H Z
- 18 -
Function
Light intensity = last DMX value
Light intensity = 0
Light intensity = manual value
Function
Display = OFF after 2 minutes
Display = always ON
Function
DMX address
DMX value
Function
Fan speed (YYY = RPM)
Maximum measured
X X X
speed of the fan (rpm)
0
F F
For development use
LED voltage (volts)
U
U
PSU voltage (volts)
Maximum / minimum
C °
temperature (°C)
Hour counter
X X X
(PSU = ON)
Hour counter
X X X
(LED = ON)
DMX rate (Hz)
X X X
EN