ORGAPACK OR-P 400 HD
7
7.1 ADJUSTING TENSIONING FORCE
– Set air pressure at pressure reducing valve of
maintenance unit to 5.7–6.2 bar.
– With a hex screwdriver adjust adjustment screw
(11/1) of air motor, so that the motor stops when the
required tension is reached. Turning the screw
clockwise the tension is reduced, turning counter-
clockwise tension is increased.
7.2 ADJUSTING WELDING TIME
– Remove the cap over the setting screw (12/1).
– The welding time can be infi nitely adjusted with a
screwdriver (no 0), depending on strap quality and
dimension.
– By turning the screw carefully clockwise (
welding time will be longer, by turning counter-clock-
wise it will be shorter.
– Adjust welding time according chapter 6.2, Fig. 10/2.
– Replace the cap over the setting screw.
7.3 ADJUSTING COOLING TIME
– Remove the cap over the setting screw (13/1).
– The cooling time can be infi nitely adjusted with a
screwdriver (no 0), depending on strap quality and
dimension.
– By turning the screw carefully clockwise (
cooling time will be longer, by turning counter-clock-
wise it will be shorter.
– Insert strap and perform a welding.
adjusted cool time should allow the strap joint to
cool for approximately 3 to 5 seconds.
Cool time which is too short may lead to
strap joint seperation.
– Replace the cap over the setting screw.