Procedure
1. Remove plastic cap from water valve inlet port.
A
A. Water valve inlet port
Cap removal
2. Place brass nut and brass sleeve on copper tubing
(Brass nut and sleeve are found in literature packet).
Insert copper tubing into water valve inlet port.
Connect brass nut on copper tubing to water valve
inlet port. Start connection by hand then use a
mm) open end wrench. Make sure copper tubing is
secure by pulling on copper tubing.
E
A. "P" clamp
C. Brass sleeve
E. Water valve inlet port
Connect ice maker water suppy line
3. Turn on water supply to refrigerator and check for
leaks. Correct any leaks at connection. Be careful not
to overtighten connection.
4. Create a service loop using extreme care to avoid
kinks. Secure copper tubing to refrigerator cabinet
with a "P" clamp.
5. Proceed to Leveling Refrigerator for final refrigerator
placement.
6. Review Installation Checklist in Owner's Manual with
consumer.
B
B. Plastic cap
1
/
" (13
2
A
B
C
D
B. Copper Tubing
D. Brass nut

Controls

This refrigerator operates at household temperatures of
55° to 110°F (13° to 43°C).
Fresh Food and Deepfreeze
Fresh Food and Deepfreeze
center divider between Fresh Food and Deepfreeze
sections.
When Deepfreeze
®
control is set to OFF , neither Fresh
®
Food nor Deepfreeze
controls to 4 . Wait 24 hours for Fresh Food and
Deepfreeze
®
sections to reach desired temperatures.
After 24 hours, adjust controls, one number at a time, as
desired. 1 is warmest setting and 7 is coldest.

Setting Controls

Set controls precisely with a household thermometer that
includes temperatures between -5° to 50°F
(-21° to 10°C).
Put thermometer snugly between frozen packages in
®
Deepfreeze
section. Wait 5-8 hours. If Deepfreeze
temperature is not 0° to 2°F (-17° to -16°C), adjust
control, 1 number at a time. Check again after 5-8 hours.
Put thermometer in a glass of water in middle of Fresh
Food section. Wait 5-8 hours. If Fresh Food temperature
is not 38° to 40°F (3° to 4°C), adjust control, 1 number at
a time. Check again after 5-8 hours.

Exterior Moisture Control

Exterior Moisture Control is located on center divider
between Fresh Food and Deepfreeze
In humid conditions, refrigerators form condensation
around doors. Special heaters in refrigerator cabinet
minimize condensation.
Humidity depends on location of refrigerator. Set control to
ON if refrigerator is in a humid area or whenever moisture
is evident around doors. Set control to OFF if refrigerator
is in a less humid area. Setting can be adjusted as
conditions change.
High quality steel is used in this refrigerator. However,
constant exposure to moisture may cause refrigerator
cabinet to rust. Set control to ON anytime condensation
forms on refrigerator cabinet.
7
®
Controls
®
controls are located on
sections will cool. Initially, set both
®
sections.
®
®