Télécharger Imprimer la page

Kohler K-1913 Guide D'installation page 39

Masquer les pouces Voir aussi pour K-1913:

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting Procedures (cont.)
Symptoms
11. The seal continuously
attempts to inflate while
bath is full.
Kohler Co.
Probable Causes
F.
Error code in controller has
been activated (beeping sound
heard).
G. The drain valve is not working.
H. The controller is not working.
A. The primary seal system is not
operating properly.
B. The secondary seal systems are
not operating properly.
C. The airline hose is pinched or
disconnected inside the door.
D. The air pressure switch is not
working.
E. The compressor is damaged.
F.
Error code in controller has
been activated (beeping sound
heard).
39
Recommended Action
F1. Reset the controller. To do this;
lower the door
quickly tap the door switch 5
times
wait 3 seconds, then tap the
switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
F2. If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.
G. Replace the drain valve or call the
Customer Care Center using the
information provided on the back
page of this manual.
H. Replace the controller or call
Customer Care Center using the
information provided on the back
page of this manual.
A. Call the Customer Care Center
using the information provided on
the back page of this manual.
B. Call the Customer Care Center
using the information provided on
the back page of this manual.
C. Call the Customer Care Center
using the information provided on
the back page of this manual.
D. The air pressure switch needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
E. The compressor needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
F1. Reset the controller. To do this;
lower the door
quickly tap the door switch 5
times
wait 3 seconds, then tap the
switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
1128532-2-C

Publicité

loading