Troubleshooting Procedures (cont.)
Symptoms
10. Bath water empties
prematurely.
1128532-2-C
Probable Causes
F.
Error code in controller has
been activated (beeping sound
heard).
G. There is a loose wire connection
in the door.
H. Limit switch is not working.
I.
The controller is not working.
A. Toe tap drain is open and does
not close or is leaking.
B. Level sensor wires are too close
together, resulting in
interference.
C. One or both of the level sensors
are not properly connected.
D. One or both of the limit
switches are not making contact
or are damaged.
E. The drain valve is connected to
another 120 V outlet and/or is
not plugged into the controller.
Recommended Action
F1. Reset the controller. To do this;
lower the door
quickly tap the door switch
after a 3 second pause and tap
the switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
F2. If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.
G. Call the Customer Care Center
using the information provided on
the back page of this manual.
H. The limit switch needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
I.
Replace the controller or call the
Customer Care Center using the
information provided on the back
page of this manual.
A. Close and/or clean the toe tap
assembly. Reseal and reattach the
drain. Replace if needed.
B. Separate the level probe wires at
both ends.
C. Firmly connect the level sensor.
D1. Adjust the limit switch/switches
until contact is made.
D2. The limit switch/switches need to
be replaced. Call the Customer
Care Center using the information
provided on the back page of this
manual.
E. Plug the drain valve directly into J2
in the controller.
38
Kohler Co.