6.1
Integration into dust-stop partition wall
You can operate the product with an extraction hose or integrate it directly into a dust-stop partition wall with
the dust-stop partition wall adapter and vacuum dust out of the inside of the dust-stop partition wall without
the product being directly in the room. To operate the product with an intake hose connected or integrate
the product directly into a dust-stop partition wall, the shutters on both sides of the product must be closed.
1. Pull the dust-stop partition wall adapter off air inlet cover (1).
2. Position the product at the dust-stop partition wall.
3. Use the dust-stop partition wall adapter to secure the dust-stop partition wall to the air inlet.
Turn the dust-stop partition wall adapter through 180° so that the inner ring fits into the air inlet.
4. If necessary, cut an opening into the dust-stop partition wall secured to the air inlet.
5. Shut off the side filters by pulling the shutter up.
6. Switch the tool on.
6.2
Replacing pre-filters
1. Switch the product off and wait until the turbine runs down to a complete stop.
2. Open the pre-filter cover (1).
3. Remove the pre-filter and insert a new pre-filter (2).
4. Remove dust residues.
5. Close the pre-filter cover (3).
6.3
Replacing main filters
1. Switch the product off and wait until the turbine runs down to a complete stop.
2. Open both toggle catches and remove the housing cover by lifting it up (1).
3. Remove heavy accretions of dust inside the housing with a vacuum cleaner.
Ascertain the dust class of the dust and use a vacuum cleaner approved for the dust class.
4. Remove the pre-filters (2).
5. Remove dust residues.
6. Open the rotary catches (3) and replace the main filter (4).
7. Replace the pre-filters (5).
8. Lower the housing cover into position (6) and seal the filter cover by closing the toggle catches (7).
7
Care and maintenance
WARNING
Electric shock hazard! Attempting care and maintenance with the supply cord connected to a power outlet
can lead to severe injury and burns.
▶ Always unplug the supply cord before carrying out care and maintenance tasks.
Care
Carefully remove stubborn dirt from the tool.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may lead to serious injuries including
burns.
▶ Repairs to the electrical section of the tool or appliance may be carried out only by trained electrical
specialists.
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.