4.2
Volumetric flow rates and vacuum
AIC 1000
Max. volume flow rate (Outlet)
Max. dispensing rate (Turbine)
Max. vacuum
4.3
Volumetric flow rates and vacuum
AIC 2000
Max. volume flow rate (Outlet)
Max. dispensing rate (Turbine)
Max. vacuum
4.4
Noise and vibration information (measured in accordance with EN 60335)
Sound power level (L
WA
Sound pressure level (L
Uncertainty
5
Use of extension cords
Use of extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if it is damaged
while work is in progress. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and replace it if it is damaged.
Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The appliance may otherwise suffer a drop in performance and the extension cord may
overheat.
Regularly check the extension cord for damage.
Replace damaged extension cords.
Information on recommended minimum conductor cross-sections and cable lengths is accessible via
a link, in the form of a QR code, at the end of this document.
6
Operation
You achieve optimum cleaning power when you operate the product without hoses connected and with the
shutter open. Depending on the conditions and the application, you can connect an intake hose or position
the product directly in a dust-stop partition wall.
The product has 2 air-cleaning stages. In operation, use stage 2 with the higher cleaning power. The stage 1
setting is only for post-cleaning the air. It can be activated when the room is unoccupied.
Before work starts, remove the air inlet cover.
1. Make sure that the product is steady and cannot topple.
2. To switch on, turn the control switch to the stage 2 position (full power).
3. To switch off, turn the control switch to the OFF position.
14
English
100 V
955 m³/h
1,475 m³/h
390 Pa
220-240 V
1,600 m³/h
2,295 m³/h
880 Pa
AIC 1000
)
76.2 dB(A)
)
62.8 dB(A)
pA
3 dB(A)
110 V
220-240 V
982 m³/h
861 m³/h
1,495 m³/h
1,425 m³/h
410 Pa
380 Pa
AIC 2000
82.7 dB(A)
69.3 dB(A)
3 dB(A)
2297300