INSTALLATION MANUAL
UCA3
3-Door standalone controller (Radio/Proximity)
Default values
- Master tag: None.
- User tag: None.
- Relay time delays : 1 second
in monostable mode.
- Security time-delay programming : 2 mins.
B - TO ACCESS THE MAIN MENU
- Press the PROG key to enter the programming mode and to open the main menu.
- The fi rst green LED is fl ashing.
- Access the fi ve menus featured in the main menu :
Menu 1
Door assignment, code entry and cancellation.
Menu 2
Time delay programming for relays.
Menu 3
Not used.
Menu 4
Master tag programming, choice of front panel reader or auxiliary reader 1.
Menu 5
Identifi cation of entry codes.
- Navigate around the main menu using the Next and Previous menu keys.
- Only one LED fl ashes at a time.
- Select the menu you wish to open. After you have selected a menu, the green LED is lit up and steady.
You may return to the main menu at any point, by pressing the PROG key.
The LED switches from steady to fl ashing. Press this button a second time to exit the
programming mode and return to normal functioning mode. All LEDS are off.
C - TO PROGRAM AND CANCEL A TAG
Proximity tags
Proximity tags can be programmed on the doors 1 and 2 :
- DOOR 1 > Controlled by the auxiliary reader 1,
- DOOR 2 > Controlled by the auxiliary reader 2.
To program tags, assign the required doors (1 and/or 2) and present the tags in front of the built-in reader
on the UCA3 front panel. All tags that you program will have the same door assignments.
Radio frequency
The radio frequency can be programmed on the doors 1 and 3 :
cdvi.com
6
cdvigroup.com
Push button controls
The push button connections are designed
to control the relays 1 and 2 separately
(the mode and time delay can be programmed).