Télécharger Imprimer la page

Kärcher CVS 65/1 Bp Mode D'emploi page 16

Publicité

Lock
1
Side brushes
2
Mount
3
1. Remove the waste container.
2. Take the battery out.
3. Tilt the device to the rear and secure it against tipping down.
4. Unscrew the lock on the underside.
a Open: Turn anticlockwise
b Close: Turn clockwise
5. Remove the side brush.
6. If necessary, clean the mount.
7. Connect the new side brush to the mount and fasten it in place
with the lock.
Check / change roller brush
Check and change the roller brush with the device tilted.
ATTENTION
Risk of injury and damage
Remove the rechargeable battery and the sweep container be-
fore tilting the device.
Secure the tipped device before replacing the roller brush.
When inserting the new roller brush, make sure that no bristles
are caught in the hole of the roller brush swing arm.
Bearing shell
1
Roller brush
2
Drive journal
3
Distance between sealing strip and retaining plate
4
– Target value: 31–33 mm
1. Take the battery out.
2. Remove the waste container.
3. Tilt the device to the rear and secure it against tipping down.
4. Remove the wrapped ribbons and cords from the roller brush.
5. Remove dirt from the drive journal.
6. To change the roller brush, grasp the roller brush by the base
body. press to the left and pull out downwards.
16
7. Fit the new roller brush on the drive journal (left). On the oppo-
site side, latch the bearing shell in the hole of the rotary brush
swing arm.
8. When the device is tilted, check the adjustment of the front
sealing strip, readjust if necessary.
Replacing / setting the sealing strips
Sealing strips
Side sealing strips
Front sealing strip
Rear sealing strip
Front sealing strip
1
Side sealing strip
2
Rear sealing strip (not adjustable)
3
Fastening
4
Waste container
5
1. Unfasten the fastening of the sealing strips.
2. Set the sealing strip by shifting it in the elongated holes.
a Refer to the table for the values.
3. Once the settings are correct, fasten the sealing strips.
Troubleshooting guide
Note
Contact the Customer Service department in the case of any
faults not listed!
Roller brush/side brush not running or running
 Switch off the on/off switch (position I).
 Charge the rechargeable battery.
 Latch the rechargeable battery in place correctly.
 Electronics switched off the device due to overload (LED flash-
es). When switching on again, note:
a Switch off the device using the on/off switch.
b Raise the roller brush by lifting the twist grip and turning it all
the way up anticlockwise.
c Switch on the device at the on/off switch.
 Check the roller brush / side brush for any tangled pieces of
tape.
 Check the belt.
 Fully close the device cover (cover switch).
Dust when sweeping / insufficient suction power
 Empty the waste container.
 Check/replace seals on filter box and waste container.
 Check/clean/replace dust filter and pre-filter.
a Check that the dust filter and pre-filter are correctly seated.
b Clean the dust filter and pre-filter if they are lightly soiled.
c In case of damage or heavy soiling, replace the dust filter
and pre-filter.
 Check the sealing strips for wear / set / replace them.
 Blower defective, contact customer service.
English
Setting values
Distance from floor 1 - 2 mm
Distance between sealing strip
and retaining plate 31–33 mm
Not adjustable
incorrectly

Publicité

loading

Ce manuel est également adapté pour:

Cvs 65/1 bp pack