Instructions
Code G : OP-MSUM034 - 046 - 057
0
1
-F1
-X1
L
N
230V1N~/50Hz
Code G : OP-MSUM068 - 080
0
1
-K1
-F2
xxA
DATE
16.12.13
DRW
u249499
model
RH
16.06.14
APPR
u249499
model
06.02.14
RH
REV
DATE
NAME
NORM
DIN61346
-F1
-X1
L
N
230V1N~/50Hz
Legend
BK
black
BU
blue
BN
brown
GY
grey
RD
red
WH
white
DATE
DRW
APPR
APP
REV
DATE
NAME
NORM
2
3
1
3
5
-K1
-F3
3A
2
4
6
1
3
5
-F2
xxA
2
4
6
-C1
-R1
N1
S
C
R
M
-M1
1~
PE
PE
PE
2
3
1
1
3
5
-F3
3A
2
4
6
2
1
3
5
95
97
98
96
2
4
6
wiring diagram/Schaltplan/plan de circuits
OP-MSUM034MLW05G
OP-MSUM046MLW05G
OP-MSUM057MLW05G
-C1
-R1
N1
N2
-X1
S
S
C
R
M
-M1
1~
PE
PE
PE
A1*
Voltage relay (option)
B1*
Fan speed controller (option)
B2
High and Low pressure switch
C1
Run capacitor compressor
C2
Start capacitor compressor
C3
Run capacitor fan
E1
Crankcase heater
F1, F3
Fuse (control circuit)
F2
Overload relay
wiring diagram/Schaltplan/plan de circuits
16.06.14
u249499
u249499
OP-MSUM068MLW05G
OP-MSUM080MLW05G
DIN61346
FRCC.EI.026.A5.02 © Danfoss Commercial Compressors 09/14
4
-A1
1
2
21
-K1
16 18 15
95
97
22
98
96
N2
1
2
-C3
1
M
-E1
-M2
1~
2
-X1
PE
4
5
-A1
L1
L2
L3
P
N
21
-K1
16 18 15
22
(114X7061)
(114X7063)
(114X7065)
1
2
-C3
1
-E1
-M2
1~
2
M
-X1
PE
(114X7067)
(114X7069)
5
6
L1
SM500
L2
L3
MG73BF
OP-MSUM034MLW05G
P
OP-MSUM046MLW05G
N
OP-MSUM057MLW05G
26 28 25
-K1
A1
A2
3
4
5
6
-B1*
2
P
PE
1
-S1*
6
-F2
SM500
MG73BF
OP-MSUM068MLW05G
OP-MSUM080MLW05G
26 28 25
Commercial Compressors
-K1
A1
A2
3
4
5
6
-B2
-B1*
2
P
PE
1
-S1*
-X1
F4
Compressor thermal protector
M1
Compressor
M2
Fan motor
K1
Contactor
K2
Start relay
R1
Bleeder resistor
S1*
Room thermostat (option)
X1
Terminals
*
Option (remove bridge)
DEPT.
CC-RCU
Commercial Compressors
8
7
-F2
19A
25A
26A
7
8
-B2
A
P<
B
P>
D
PE
C
-X1
PE
7
8
32A
38A
=
+
DEPT.
DRAWING-NO.
CC-RCU
118R0112
7
8
A
P<
B
P>
D
PE
C
PE
=
+
DRAWING-NO.
118R0161
9
9
SHEET
OF
1
SHEET
1
7
OF
1