1
User
The CPV valve terminal with field bus direct connection
(CPV Direct) is intended exclusively for use with the
Beckhoff field bus box.
The maximum values specified in the section Technical
specifications" must be observed here. Detailed informa
tion can be found in the manual P.BE−CPV−DI−IP−.. .
Warning
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Use only power units which guarantee reliable isola
tion of the operating voltages as per IEC 742/
EN 60742/VDE 0551 with at least 4 kV isolation resis
tance (Protected Extra Low Voltage PELV). Switch
power packs are permitted, providing they guarantee
reliable isolation in accordance with EN 60950/
VDE 0805.
S Connect an earth conductor of sufficient cross−
sectional area to the terminal marked with the earth
symbol.
S Commission only a CP system which has been fitted
and wired completely.
If the terminal is to be used as an explosion−proof oper
ating media, make sure that:
S the electrical connections are not disconnected when
power is still applied.
S the completely fitted product with all plugs, adapters
and protective caps used complies at least with
protection class IP64.
Festo CPV..−GE−IP−8 0211NH English
instructionsEnglish
11