420010311000 Multicalor 1500.1 - 1800.1 PR/PR
EN
PRESSURE REGULATING VALVE ADJUSTMENT
1) Remove the cap A of the pres-
sure regulating valve TV.
B
2) Loosen the fixing nut B and
use an allen wrench on the screw
C to adjust the delivery oil pres-
A
sure. To increase the pressure
C
turn clockwise, to decrease the
pressure turn anticlockwise.
3) Tighten the nut B and pay
attention not to turn also the
adjusting screw.
4) Screw on the cap A, back to
its previous position.