Note : The bypass plug inserted beween high pressure and shaft seal is only intended to change the pump rotation,
check the presence of this plug with a 4 mm Allen key in the pressure outlet of the pump.
Caution : changing the direction of pump rotation involves changing of all pump connections.
IDENTIFICATION
(Not all model combinations are available
Consult your Suntec representative)
T
2
Preheater
facility
Revision number
General
Mounting
Connection threads
Inlet end return
To nozzle
Pressure gauge port
Vacuum gauge port
Shaft
Weight
Hydraulic data
Nozzle pressure range
Operating viscosity
Oil temperature
Inlet pressure
Rated speed
Starting torque
Choice of heater
Cartridge
Fitting
Rating
PUMP SUNTEC T TECHNICAL DATA
PUMP
T :
type
Gear set capacity
(see pump capacity curves)
Shaft rotation
(seen from shaft end)
A :clockwise rotation
C : anti clockwise rotation
A
10
6
Flange mounting
Cylindrical according to ISO 228/1
G 1/2"
G 1/2"
G 1/4"
G 1/4"
Ø 20 mm
7,8 kg (T2)
-
8,1 kg (T3)
8,7 kg (T4)
-
9,4 kg (T5)
40 bars max. (T2, T3, T4)
30 bars max. (T5)
4 - 450 cSt
0 - 150°C max. in the pump
light oil :
0,45 bars max. vacuum to prevent
air separation from oil
heavy oil :
5 bars max.
3600 rpm max.
0,4 N.m
Ø 12 mm
according to DIN 40430, NFC 68190 (N°9 elec.)
80-100 W
420010311000 Multicalor 1500.1 - 1800.1 PR/PR
Oil under suction
Oil under pressure
Vacuum or
Pressure
inlet pressure
gauge port
gauge port
Intake
from Tank
Plug inserted between
high pressure and shaft seal
regulating valve
Intake from Tank
Capacity (L/h)
4200
T5
4000
3800
3600
3400
3200
3000
T4
2800
2600
2400
T3
2200
2000
1800
T2
1600
1400
1200
1000
0
5
10
Viscosity =
Data shown are for new pumps, with no allowance for wear.
Power consumption
25
To
pressure
regulating
valve
To
pressure
Pump capacity
2850 rpm
15
20
25
30
35
40
Pressure
(bars)
200 cSt
20 cSt
5 cSt -
Rated speed = 2850 rpm
EN