Switch off without delay
Push button
twice.
1
Levels of intensity
To increase speed levels push button
To decrease speed levels push button
Three green LED's
indicate level 1 to 3, one red LED
5
indicates the level 'POWER'. 'POWER' is only used in
6
case of excessive formation of smoke, fumes or odours.
Taking into account the large volume of air which is ex-
tracted from the room at this level, it's use should be
limited. 'POWER' automatically reverts to level 3 after 6
minutes.
A self-rectifying thermal contact makes sure that the
motor is switched off when overheated. The motor will
switch on again after is has cooled down. The cause of
the overheating needs to be determined. This may be,
for example, that the contents of the pan have caught
fire, the motor fan is blocked or an object is (partly) clo-
sing off the exhaust opening.
Auto-Stop
To avoid that the hood will function during a too long pe-
riod, it will switch off automatically after 3 hours (when
no changes to the controls have been made). Motor
and lighting will turn off automatically.
3.2
To activate the lights press button
switch on at full power. Lighting can be activated inde-
pendently from the motor.
.
3
If the lighting is defective, please contact your installer
or Novy.
3.3
If recirculation has been chosen, this is to be program-
med one time. This programming activates the cleaning
indication of the Monoblock recirculation filter and chan-
.
2
ges the switch-off delay time.
Programme
ched off):
Simultaneously press the
conds until the red LED flashes 5 times. The following
functions have now been enabled:
Deactivate the programming
ming with the motor turned on):
Simultaneously press
green LED flashes 3 times. Attention!

Lightning

Recirculation (option)
(do the programming with the motor swit-
2
The run-out time has been set to 30 minutes (instead
of the default 10 minutes). Make use of the 30 minu-
tes run-out time.
The cleaning indicator for the Monoblock recirculati-
on filter has been set to 400 operating hours.
The red LED will light up after 400 operating hours.
This indicates that the Monoblock recir-culation filter
needs cleaning
and
2
. The lights will
4
and the
keys for 3 se-
3
(do the deactivate program-
for 3 sec. until the third
3
EN 29