I. INSTALLATION.
It is important to follow all instructions shipped with this product. This device is to be installed by
a trained electrician who is thoroughly familiar with the National Electrical Code and will follow
the NEC Guidelines as well as local codes.
The selection of the mounting location for the device, its controls and the routing of the wiring is
to be accomplished under the direction of the facilities engineer and the safety engineer.
In addition, listed below are some other important safety instructions and precautions you
should follow:
• Read and understand all instructions before installing or operating this equipment.
• Do not connect this light to the system when power is on.
• After installation, test the light system to ensure that it is operating properly.
• After testing is complete, provide a copy of this instruction sheet to all operating personnel.
• Establish a procedure to routinely check the light system for proper activation and operation.
Failure to follow all safety precautions and instructions may result in property damage, serious
injury, or death to you or others.
A. Unpacking.
After unpacking the Model 225, examine it for damage that may have occurred in transit. If the
equipment has been damaged, do not attempt to install or operate it, file a claim immediately
with the carrier stating the extent of the damage. Carefully check all envelopes, shipping labels
and tags before removing or destroying them.
B. Mounting.
The Model 225 can be mounted on a flat surface or a 1/2-inch pipe, as shown in figure 1.
The Model 225 is UL Listed and has been investigated by UL and meets Type 4X (watertight
and corrosion resistant) enclosure requirements. It also meets IP 66 (dust-tight and protection
against heavy seas) enclosure requirements. Hardware and installation details are left to the
user.
To comply with the Type 4X and IP66 enclosure reqiurements, the light must be mounted in
C. Electrical Connections.
Connect the black and white power leads to a 120VAC power source.
A green/yellow wire is provided for connection to earth ground, when required by building
codes.
INSTRUCTION SHEET FOR FEDERAL SIGNAL
MODEL 225 Electraray® LIGHT
SAFETY MESSAGE TO INSTALLERS
the DOME UP position.
Do not connect wires when power is applied.
NOTE
WARNING
-1-