Start-up
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Dynamic Function
How to proceed:
I
• Slide the switch.
– ON: The function is activated.
– OFF: The function is deactivated.
Note!
When the Dynamic Function is activated, the function of the EFC (Environmental Function Control) is limited.
• The unit is not protected from running dry.
Remedy of faults
Malfunction
Pump does not start.
Pump does not deliver.
Insufficient delivered quantity
Pump switches off after a short running period.
Height of the fountain varies.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Cleaning the unit
Note!
Recommendation on regular cleaning:
• Clean the pump at least twice a year.
• Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
How to proceed:
J
1. Turn the filter basket counterclockwise and remove.
– The filter basket is fastened to the pump with a bayonet lock.
2. Clean all parts.
– Use a soft brush.
– Rinse parts in clean water.
3. Reassemble the unit in the reverse order.
40403-10-14_GA_PondJet_Eco.pdf 17
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Excessively soiled water
Water temperature too high
Impeller unit blocked
Pump has run dry.
Dynamic Function activated
- GB -
Remedy
Check the mains voltage.
Check supply lines.
Clean
Clean
Clean pump. The pump automatically switches
on again once the motor has cooled down.
Note maximum water temperature of +35°C.
The pump automatically switches on again
once the motor has cooled down.
Disconnect the power supply and remove
obstacle. Then switch the pump on again.
Flood pump. Fully submerge the unit when
operated in the pond.
Deactivate Dynamic Function