- GB -
Fitting the nozzle
Multifunctional nozzle
How to proceed:
E
1. Unscrew the plug and remove together with the cover disk and both O-rings.
2. Screw in the plug with O-ring and tighten.
– The outlets of the multifunctional nozzle are now uncovered.
Optional nozzle
Connection: 25 mm (1 ")
How to proceed:
F
1. Unscrew the plug with O-ring and remove.
2. Screw in the optional nozzle with O-ring and tighten.
– The nozzle is now ready for use and the outlets of the multifunctional nozzle are closed off.
Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries due to operation of this unit in a swimming pond.
Protective measures:
• Do NOT use this unit in a swimming pond.
• Adhere to national and regional regulations.
G, H
The unit floats on the water and therefore has to be moored to the edge or base of the pond (e.g. with nylon ropes).
• Necessary minimum depth of water: 0.5 m
Mooring to the edge of the pond
• Attach the ends of the nylon ropes to the three holes in the float.
• Position the unit in the water and attach the other ends of the nylon ropes to the edge of the pond, ensuring that
they are uniformly distributed around the edge of the pond.
• Only moderately tension the nylon ropes to allow for fluctuations in the water level.
• If the nylon ropes present a hazard, secure the entire area around the unit.
• The connection cable must be provided with strain relief.
Mooring to the bottom of the pond
• Determine the depth of the water and cut three nylon ropes to length (depth of the water plus 1 m).
• Attach the ends of the nylon ropes to the three holes in the float.
• Attach the other ends of the nylon ropes to a weight (approx. 20 kg).
• Position the unit in the water and lower the weight to the bottom of the pond.
• Ensure that the nylon ropes are not tensioned in order to allow for fluctuations in the water level.
• The connection cable must be provided with strain relief.
16
40403-10-14_GA_PondJet_Eco.pdf 16
10.10.2014 12:00:31