WATER PIPING - MIXING VALVE USAGE

Mixing Valves

DANGER
HOT
HOT
BURN
Water heated to a temperature which satisfi es space
heating, clothes washing, dish washing, and other
sanitizing needs can scald and cause permanent injury
upon contact. Short repeated heating cycles caused by
small hot-water uses can cause a temperature increase
of the hot water by 11C° (20F°) higher than the heater's
temperature settings.
TEMPERED
POTABLE WATER
MIXING
VALVE
TEMPERATURE-
PRESSURE
RELIEF VALVE
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
* NOTE: THE
T&P VALVE
DISCHARGE
PIPE MUST
BE PIPED
DIRECTLY TO
THE DRAIN
OR EXTERNAL
TO THE
BUILDING
DRAIN
VALVE
Figure 7
328765-000
All manuals and user guides at all-guides.com
Water temperature over
125°F (52°C) can cause
severe burns instantly
resulting in severe injury or
death.
Children, the elderly and the
disabled and are at highest
risk of scald injury.
Feel water before bathing or
showering.
Temperature limiting devices
such as mixing must be
installed when required by
codes and to ensure safe
temperatures at fixtures.
SUGGESTED PIPING ARRANGEMENT
FOR TOP CONNECTIONS
SHUT-OFF
VALVE
COLD-WATER
INLET
CERTAIN MODELS
ARE EQUIPPED WITH
SIDE PLUMBING
CONNECTIONS FOR
SPACE HEATING.
THE HOT AND
COLD FITTING
ASSEMBLIES (PART
#9001262005) CAN
BE ORDERED
THROUGH THE
MANUFACTURER
METAL DRAIN
PAN 45mm (1.75")
MAX. DEPTH. AT
LEAST 50mm (2")
GREATER THAN THE
DIAMETER OF THE
WATER HEATER.
305mm (12")
MAX. AIR
GAP*
www. gsw-wh .com
This appliance has been design certifi ed as complying
with CSA Standard for water heaters and are considered
suitable for combination Water (Potable) Heating and
Space Heating but not space heating only applications.
The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed
on the supply to the entire house in order to maintain equal
hot and cold water pressures.
TEMPERED
POTABLE WATER
NON-TEMPERED
WATER SUPPLY
SUGGESTED PIPING
ARRANGEMENT FOR
TOP CONNECTIONS
TEMPERATURE-
PRESSURE
RELIEF VALVE
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
* NOTE: THE
T&P VALVE
DISCHARGE PIPE
MUST BE PIPED
DIRECTLY TO
THE DRAIN OR
EXTERNAL TO
THE BUILDING
DRAIN
VALVE
Figure 8
SHUT-OFF
VALVE
COLD-WATER
INLET
NON-TEMPERED
WATER RETURN
MIXING VALVE
METAL DRAIN
PAN 45mm
(1.75") MAX.
DEPTH. AT
LEAST 50mm
(2") GREATER
THAN THE
DIAMETER OF
THE WATER
HEATER.
305mm
(12") MAX.
AIR GAP*