Water Heater; Vent Pipe Termination - GSW 6G40NAV Mode D'emploi

Table des Matières

Publicité

WATER
HEATER
HEATER
INPUT
(Inside
MODEL
(Btu/hr)
Diam.)
40 gal.
40,000
50 gal
45,000
40 gal.
40,000
50 gal
45,000
58,000
50 gal.
62,000
72,000
75 gal.
76,000
40 gal.
40,000
50 gal
45,000
58,000
50 gal.
62,000
72,000
75 gal.
76,000
* see Figure 27 and Figure 28
Equivalent lengths of straight pipe for various elbows using
Schedule 40 PVC, CPVC, ABS, and polypropylene.
Vent Pipe
Elbow
Size
Type
2"
3"
90°
4"
2"
3"
45°
4"
Table 3
328765-000
All manuals and user guides at all-guides.com
VENT
2 PIPE MAX.
SIZE
EQUIV. VENT
LENGTH
50' (15m) + term.
2"
elbow and screen*
125' (38m) + term.
3"
elbow and screen*
50' (15m) + term.
3"
elbow and screen*
180' (55m) + term.
4"
elbow and screen*
125' (38m) + term.
4"
elbow and screen*
Short Sweep/
Long Sweep/
Radius
Radius
8' (2.44m)
5' (1.5m)
4' (1.22m)
2.5' (0.76m)

Vent Pipe Termination

This water heater includes one (1) pair of more restrictive
Vent Termination Screens and one (1) pair of less
restrictive Vent Termination Screens. For safety and
optimum effi ciency performance, ensure the correct Vent
Termination Screen is installed for the vent length in your
installation.
Note: Before installing the Power Direct Vent Water
Heater, it is recommended that the location of the pipe
terminations (air intake and exhaust vent) be determined.
Use the Vent Termination Screen as shown in Figure 27
& Figure 28. Install the Vent Termination Screen in the
Termination Elbow on both the air intake pipe and the
exhaust pipe.
2 PIPE
MIN. EQUIV.
VENT LENGTH
7' (2m) + term.
elbow and screen*
7' (2m) + term.
elbow and screen*
125' (38m) + term.
elbow and screen*
50' (15m) + term.
elbow and screen*
Notes:
1. Vent lengths shown do not include vent termination
elbow.
2. A horizontal vent must have a 45° vent termination
elbow to direct the vent pipe downward.
3. A vertical vent must have a 90° elbow to direct the
vent pipe horizontally followed by a vent termination
45° elbow to direct the vent pipe downward.
4. If additional elbows are used in the vent system
the allowable vent lengths are reduced (see chart
below).
5. Two 45° elbows are considered the equivalent of
one 90° elbow.
6. The equivalent length of the sound suppressor is
similar to that of a short sweep 90° elbow.
www. gsw-wh .com
CONC. VENT
CONC. VENT
MAX. EQUIV.
MIN. EQUIV.
VENT LENGTH
VENT LENGTH
50' (15m) + term.
7' (2m) + term.
elbow and screen*
elbow and screen*
100' (30m) + term.
elbow and screen*
7' (2m) + term.
elbow and screen*
30' (9m) + term.
elbow and screen*
N/A
N/A
27