GAS CONTROL VALVE/THERMOSTAT
ON/OFF
TEMPERATURE
SWITCH
SETTING DIAL
Figure 39
Approximate
Temperature
Temperature
Dial Setting
°C (°F)
VERY HOT
68 (155)
C
65 (150)
B
60 (140)
A
54 (130)
HOT
49 (120)
LOW
43 (110)
VAC
21 (70)
Table 4
Note: The temperatures indicated are approximate. The
actual temperature of the heated water may vary.
The Vacation Setting (VAC) sets the controller at
approximately 21°C (70°F). This setting is recommended
when the water heater is not in use for a long period of time.
This effectively turns the controller temperature setting
down to a temperature that prevents the water in the water
heater from freezing while still conserving energy.
328765-000
All manuals and user guides at all-guides.com
54°C
60°C
65°C
68°C
(130°F)
(140°F)
(150°F)
(155°F)
49°C
43°C
21°C
(120°F)
(110°F)
(70°F)
Time to induce a 2nd
and 3rd Degree burn
to adult skin
Less than 1 second
About 1.5 seconds
Less than 5 seconds
More than 30 seconds
More than 5 minutes
Normal shower temp
N/A
www. gsw-wh .com
37