EXPERT SERIES
6 TRIGGER MODE : The parameters on page 5 of the menu will be active. According to the parameters set
on page 5, the 6-trigger mode will run.
You can use the 6 trigger functions to make a crater or prevent start and end welding errors.
Welding Current: 200 A, Initial current: 200%, End current: 50% and End time: Set to 2 seconds.
For instance;
In this case, the Initial current will be 400A, to be 200% of the main current. The end current will be 100 A,
that is 50% of the main current.
• Press and hold the torch trigger.
Welding Start and End;
• Shielding gas flow starts as long as the pre-gas period and continues at the initial current.
• The torch trigger is released and the current decreases during the specified start time and the main
current value is reached then the operation continues at the main current.
• Press and hold the trigger. Transition from main current to end current is done, the process continues at
the end current.
• Release the trigger when you want to finish the process, the process ends at the end of the final gas time.
welding period and ends at the end of the period. No welding will be performed if as long as the defined void
METHOD : It is the pnt welding to be mentioned in the mode. The welding continues for the specified
period. This period will continue as long as the trigger is not released.
Welding Time : 0.2-9.9 and void time : It is between 0.0 and 9.9 seconds.
It should be preferred when the same welding seam and penetration are desired every time. The lengths
of the welds made in Method mode will be equal.
When the method mode is selected, the welding time will be set.
b) ARC ON TIME
• 0.2-9.9 sec.
Setting Range
When Method mode is selected, the non-welding time will be set.
c) )ARC OFF TIME
• 0.0- 9.9 sec.
Setting Range
Adjust the speed of the wire when it first comes.
d) SOFT START
• Active / Passive
Setting Range
The fast incoming wire gives the user a sense of pushing backwards at the first moment. If you activate the
clicking setting, the wire comes slowly and accelerates as soon as the welding starts. So the feeling of push
back disappears.
www.magmaweld.com
PrG : Pre-Gas Period
: Initial current
: Start Time
IC
: Welding Current
ST
: End time
I
: End Current
FT
PoG : Final Gas Period
FC
Operation
27
EN
USER MANUAL