22
Operation
PAGE 1
EN
Menu language is selected.
a) LANGUAGE
• TR (Turkish)
Setting Range
• EN (English)
• FR (French)
• DE (German)
Welding process will be selected.
b) PROCESS
• MMA
Setting Range
• MIG/MAG
• Pulse (Pulse MIG/MAG)
• D.Pulse (Double Pulse MIG/MAG)
You need to adjust your connections and accessories according to the selected welding method. There is a
separate outlet for the MMA method in front of the machine.
Selecting from the METHOD menu creates a differentiation in the MODE menu options.
c) MODE
MMA
• Method
Setting Range
• Set / Carbon
• Rutile / Basic
If you select your source mode correctly, you will get better welded pieces. For example; the method mode
should be selected for the welding processes where continuous short welding seams will be made.
When the MIG/MAG welding method is selected in the METHOD menu, the modes will be as follows :
MIG/MAG
You can adjust your wire speed and
CLASSIC MODE
welding voltage in certain tolerance
value ranges. Wire speed will be
adjusted between 1-24 m/min,
welding voltage will be adjusted
between 15-40 V.
If you want to see which value the machine originally recommends and return to that value, simply press
the adjustment button once.
USER MANUAL
MIG/MAG
Pulse (Pulse MIG/MAG)
• Classic
• Classic
Setting Range
Setting Range
• Smart
• Smart
• Synergic
• Synergic
When selected, welding parameters
SMART MODE
such as wire type, wire diameter, gas
type must be selected correctly. The
machine will automatically adjust the
optimum voltage according to the
selected welding current. You can
adjust the voltage by turning the
adjustment knob in the +/- direction
within a certain tolerance range.
EXPERT SERIES
D. Pulse (Double Pulse MIG/MAG)
• Classic
Setting Range
• Smart
• Synergic
Welding parameters such as wire type,
SYNERGIC MODE
wire diameter, gas type and thickness
must be selected correctly. Both the
current and the voltage will be
automatically adjusted according to
the selected welding parameters. The
user can navigate both in the current
and voltage within a certain tolerance
range. The machine will automatically
recalculate the voltage according to
the current value set at the specified
tolerance.
www.magmaweld.com