(D-CE)
2006/42/CE; 2006/95/CE; 2004/108/CE; 2000/14/CE (followed pro-
cedure: annex V).
(N-A)
EN 60034...;EN 60204-1; EN 60335-1; EN 60335-2-41; EN 61000;
EN 55014;
UNI EN ISO 12100; UNI EN ISO 14121; UNI EN ISO 3744.
Group 1: models
JMC (0,59÷0,74 kW rated; 0,78÷1 kW absorbed), CAM (0,44÷2,2
kW rated; 0,59÷2,65 kW absorbed), INOX (0,59÷0,74 kW rated;
0,78÷1 kW absorbed), CAB (1,1÷2,2 kW rated; 1,65÷2,65 kW ab-
sorbed), AP (0,59÷1,65 kW rated; 0,8÷2,22 kW absorbed), PM-CP
(0,37÷0,74 kW rated; 0,49÷1,13 kW absorbed), MD (0,59÷0,74 kW
rated; 0,94÷1,17 kW absorbed), CM (0,37÷4 kW rated; 0,59÷5,1
kW absorbed); CS (0,59÷4 kW rated; 0,63÷5,05 kW absorbed); CH
(1,1÷4 kW rated; 1,9÷5,1 kW absorbed); CR (0,59÷0,74 kW rated;
0,73÷1,2 kW absorbed); CB100÷900 (0,74÷6,6 kW rated; 1,15÷7,6
kW absorbed), MB (1,1÷2,2 kW rated; 1,55÷2,65 kW absorbed);
MPX- MPA (0,59÷0,88 kW rated; 0,83÷1,33 kW absorbed).
Measured sound power level LWA: 88 dB (A)
Guaranteed sound power level LWA: 89 dB (A)
Measured sound pressure level LpA: (R: 1,5m; H: 1,5m):≤ 75 dB (A)
(rated voltage/frequency, maximum declared capacity).
Group 2: models
CBT800÷1500 (5,5÷11kW rated; 8,5÷12,1 kW absorbed); normal-
ized monobloc mod. CM (1,5÷37 kW rated; 2,3÷45 kW absorbed).
Measured sound power level LWA: 98 dB (A)
Guaranteed sound power level LWA: 99 dB (A)
Measured sound pressure level LpA: (R: 1,5m; H: 1,5m):≤ 90 dB (A)
(rated voltage/frequency, maximum declared capacity).
Manufacturer and depositary of tecnical documentation:
BOMBAS SACI, S.A.
Ctra. Mataro km 629 Pol.Ind.Ribó
08911 Badalona - Spain
David Ferré Ferrer (President)
Badalona, 1/11/2011