INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only
metal ductwork.
1. Decide where the ductwork will run between
the hood and the outside.
2. A straight, short duct run will allow the hood
to perform most efficiently.
3. Long duct runs, elbows, and transitions will
reduce the performance of the hood. Use as
few of them as possible.
4. Install a roof or wall cap. Connect 6" round
metal ductwork to cap and work back to-
wards hood location. Use duct tape to seal
the joints between ductwork sections.
INSTALL DUCT CONNECTOR
1. Fix the duct connector onto the hood; it must
be fixed either by means of mounting screws
(3.9x9.5mm).
Be careful to the position of the duct
connector (see figure).
2. Remove the tape located on the damper.
REMOVE THE TAPE
INSTALL MOUNTING
BRACKETS
1. Construct wood wall framing that is flush
with interior surface of wall studs.Make sure:
a) the framing is centered over installation
location.
b) the height of the framing will allow the
mounting brackets to be secured to the
framing within the dimensions shown.
2. After wall surface is finished, secure mount-
ing brackets to framing using dimensions
shown.
DECORATIVE
FLUE
HOOD
24" TO 30" ABOVE
COOKING SURFACE
FRAMING BEHIND DRYWALL
38-7/8"= bottom of hood 24" above cooktop
44-7/8"= bottom of hood 30" above cooktop
- 5 -
ROOF CAP
6" ROUND DUCT
6" ROUND
ELBOW
MOUNTING SCREWS
(3.9x9.5mm)
WALL
CAP